Irrigation reference
The numbers a tech uses in the yard: how much water the house can run, what the pipe loses, what each nozzle and emitter puts out, and how to find an electrical or valve problem. Same data the MyWaterBudget apps use. Updated Nov 21, 2026.
Water available: the most one zone should pull
Put a gauge on the hose bib nearest the meter with nothing running (static pressure). Read the meter size off the meter. Find the service line size: wrap a string around the pipe from the meter to the house once and measure it. Copper: 2¾" = ¾", 3½" = 1", 4⅜" = 1¼". PVC or galvanized: 3¼" = ¾", 4⅛" = 1", 5¼" = 1¼".
| Meter | Service line | 30 psi | 40 psi | 50 psi | 60 psi | 70 psi | 80 psi |
|---|---|---|---|---|---|---|---|
| ⅝" | ½" | 2 | 4 | 5 | 6 | 7 | 7 |
| ⅝" | ¾" | 4 | 6 | 8 | 8 | 10 | 12 |
| ⅝" | 1" | 4 | 7 | 8 | 10 | 13 | 15 |
| ¾" | ¾" | 4 | 6 | 8 | 9 | 10 | 12 |
| ¾" | 1" | 5 | 7 | 10 | 14 | 17 | 20 |
| ¾" | 1¼" | 5 | 12 | 17 | 20 | 22 | 22 |
| 1" | ¾" | 4 | 7 | 8 | 9 | 12 | 12 |
| 1" | 1" | 5 | 8 | 14 | 18 | 20 | 20 |
| 1" | 1¼" | 5 | 14 | 24 | 26 | 30 | 34 |
Max GPM per zone, by static pressure. Method and chart: Hunter Industries, Residential Sprinkler System Design Guide (LIT-226), "Determine System Design Capacity." The chart is for 100 ft of thick-walled PVC service line. Copper service line: take off 2 GPM. Galvanized: take off 5 GPM. Approximate working pressure at the heads for 30 / 40 / 50 / 60 / 70 / 80 psi static: 25 / 30 / 35 / 45 / 50 / 55 psi. Under 30 psi static, sprays won't perform: drip and MP Rotators only, or a booster. Over 80 psi static needs a pressure regulator (PRV) at the house. Use the calculator on the Resources page for your own house.
Pipe sizes and friction loss
Keep water under 5 feet per second. Faster than that: water hammer, fittings that work loose, and pressure lost before the heads.
| Size | Pipe | Inside dia. | Max GPM (5 ft/s) |
|---|---|---|---|
| ½" | Sch 40 | 0.622" | 4.7 |
| ¾" | Sch 40 | 0.824" | 8.3 |
| 1" | Sch 40 | 1.049" | 13.5 |
| 1¼" | Sch 40 | 1.380" | 23.3 |
| 1½" | Sch 40 | 1.610" | 31.7 |
| 2" | Sch 40 | 2.067" | 52.3 |
| ¾" | Class 200 | 0.930" | 10.6 |
| 1" | Class 200 | 1.189" | 17.3 |
| 1¼" | Class 200 | 1.502" | 27.6 |
| 1½" | Class 200 | 1.720" | 36.2 |
| 2" | Class 200 | 2.149" | 56.5 |
| ½" | Drip tubing | 0.600" | 4.4 |
| ¼" | Drip micro tubing | 0.170" | 0.4 |
Max GPM = 2.448 × 5 ft/s × inside diameter². Inside diameters are typical; check the pipe you buy.
Friction loss, psi per 100 ft of pipe
Computed with the Hazen-Williams formula (C = 150 for PVC, 140 for poly). * = over 5 ft/s: size up. — = far too fast for that size. For a run shorter or longer than 100 ft, scale it: 50 ft = half the number.
PVC Sch 40 C = 150
| GPM | ½" 0.622" ID | ¾" 0.824" ID | 1" 1.049" ID | 1¼" 1.380" ID | 1½" 1.610" ID | 2" 2.067" ID |
|---|---|---|---|---|---|---|
| 1 | 0.43 | 0.11 | 0.03 | <0.01 | <0.01 | <0.01 |
| 2 | 1.55 | 0.39 | 0.12 | 0.03 | 0.02 | <0.01 |
| 3 | 3.28 | 0.84 | 0.26 | 0.07 | 0.03 | <0.01 |
| 4 | 5.59 | 1.42 | 0.44 | 0.12 | 0.05 | 0.02 |
| 5 | 8.45* | 2.15 | 0.66 | 0.17 | 0.08 | 0.02 |
| 6 | 11.8* | 3.01 | 0.93 | 0.25 | 0.12 | 0.03 |
| 8 | — | 5.14 | 1.59 | 0.42 | 0.20 | 0.06 |
| 10 | — | 7.76* | 2.40 | 0.63 | 0.30 | 0.09 |
| 12 | — | 10.9* | 3.36 | 0.89 | 0.42 | 0.12 |
| 15 | — | — | 5.08* | 1.34 | 0.63 | 0.19 |
| 20 | — | — | 8.66* | 2.28 | 1.08 | 0.32 |
| 25 | — | — | — | 3.45* | 1.63 | 0.48 |
| 30 | — | — | — | 4.83* | 2.28 | 0.68 |
PVC Class 200 (SDR 21) C = 150
| GPM | ¾" 0.930" ID | 1" 1.189" ID | 1¼" 1.502" ID | 1½" 1.720" ID | 2" 2.149" ID |
|---|---|---|---|---|---|
| 1 | 0.06 | 0.02 | <0.01 | <0.01 | <0.01 |
| 2 | 0.22 | 0.07 | 0.02 | 0.01 | <0.01 |
| 3 | 0.46 | 0.14 | 0.04 | 0.02 | <0.01 |
| 4 | 0.79 | 0.24 | 0.08 | 0.04 | 0.01 |
| 5 | 1.19 | 0.36 | 0.12 | 0.06 | 0.02 |
| 6 | 1.67 | 0.51 | 0.16 | 0.08 | 0.03 |
| 8 | 2.85 | 0.86 | 0.28 | 0.14 | 0.05 |
| 10 | 4.31 | 1.30 | 0.42 | 0.22 | 0.07 |
| 12 | 6.04* | 1.83 | 0.59 | 0.30 | 0.10 |
| 15 | 9.13* | 2.76 | 0.89 | 0.46 | 0.16 |
| 20 | — | 4.71* | 1.51 | 0.78 | 0.26 |
| 25 | — | 7.12* | 2.28 | 1.18 | 0.40 |
| 30 | — | — | 3.20* | 1.65 | 0.56 |
PVC Class 315 (SDR 13.5) C = 150
| GPM | ½" 0.716" ID | ¾" 0.894" ID | 1" 1.120" ID | 1¼" 1.414" ID | 1½" 1.619" ID | 2" 2.023" ID |
|---|---|---|---|---|---|---|
| 1 | 0.22 | 0.07 | 0.02 | <0.01 | <0.01 | <0.01 |
| 2 | 0.78 | 0.27 | 0.09 | 0.03 | 0.01 | <0.01 |
| 3 | 1.65 | 0.56 | 0.19 | 0.06 | 0.03 | 0.01 |
| 4 | 2.82 | 0.96 | 0.32 | 0.10 | 0.05 | 0.02 |
| 5 | 4.26 | 1.45 | 0.48 | 0.16 | 0.08 | 0.03 |
| 6 | 5.97 | 2.03 | 0.68 | 0.22 | 0.11 | 0.04 |
| 8 | 10.2* | 3.45 | 1.15 | 0.37 | 0.19 | 0.06 |
| 10 | — | 5.22* | 1.74 | 0.56 | 0.29 | 0.10 |
| 12 | — | 7.32* | 2.44 | 0.79 | 0.41 | 0.14 |
| 15 | — | — | 3.70 | 1.19 | 0.62 | 0.21 |
| 20 | — | — | 6.30* | 2.03 | 1.05 | 0.35 |
| 25 | — | — | — | 3.06* | 1.58 | 0.54 |
| 30 | — | — | — | 4.29* | 2.22 | 0.75 |
Poly (SIDR, ID-controlled) C = 140
| GPM | ½" 0.622" ID | ¾" 0.824" ID | 1" 1.049" ID | 1¼" 1.380" ID |
|---|---|---|---|---|
| 1 | 0.49 | 0.12 | 0.04 | 0.01 |
| 2 | 1.76 | 0.45 | 0.14 | 0.04 |
| 3 | 3.73 | 0.95 | 0.29 | 0.08 |
| 4 | 6.35 | 1.62 | 0.50 | 0.13 |
| 5 | 9.60* | 2.44 | 0.76 | 0.20 |
| 6 | 13.5* | 3.43 | 1.06 | 0.28 |
| 8 | — | 5.84 | 1.80 | 0.47 |
| 10 | — | 8.82* | 2.73 | 0.72 |
| 12 | — | 12.4* | 3.82 | 1.01 |
| 15 | — | — | 5.78* | 1.52 |
| 20 | — | — | 9.84* | 2.59 |
| 25 | — | — | — | 3.92* |
| 30 | — | — | — | 5.49* |
Psi at the furthest head ≈ running psi − valve loss (MyWaterBudget uses 5 psi) − pipe friction − 0.433 psi for every foot of rise. Fittings add loss too; long runs with many fittings lose more than the straight-pipe number. Class 315 inside diameters are figured from the standard outside diameter at SDR 13.5.
Drip valve kits
Valve + filter + pressure regulator in one kit. Pick the kit whose flow range covers the zone, with enough pressure coming in to hold its rating.
| Kit | Valve | GPM range | Regulates to | Filter | Inlet max | Inlet needed at flow |
|---|---|---|---|---|---|---|
| Rain Bird XCZ-075-PRF | ¾" low-flow inline (LFV075) | 0.2–5 | 30 psi | 200 mesh · ¾" PR RBY filter | 150 psi | 34.4 psi @ 0.2 GPM, 36.1 psi @ 1 GPM, 38.1 psi @ 3 GPM, 43.4 psi @ 5 GPM |
| Rain Bird XCZLF-100-PRF | 1" low-flow inline (LFV100) | 0.2–10 | 40 psi | 200 mesh · 1" PR RBY filter | 150 psi | 44.4 psi @ 0.2 GPM, 44.4 psi @ 1 GPM, 45 psi @ 3 GPM, 46.2 psi @ 5 GPM, 52.2 psi @ 10 GPM |
| Rain Bird XCZ-100-PRF | 1" DV inline (100DV) | 3–15 | 40 psi | 200 mesh · 1" PR RBY filter | 150 psi | 42.9 psi @ 3 GPM, 44.1 psi @ 5 GPM, 46.9 psi @ 8 GPM, 48.5 psi @ 10 GPM, 55.5 psi @ 15 GPM |
| Rain Bird XACZ-075-PRF | ¾" anti-siphon low-flow (ASVLFV075) · anti-siphon | 0.2–5 | 30 psi | 200 mesh · ¾" PR RBY filter | 150 psi | — |
| Rain Bird XACZ-100-PRF | 1" anti-siphon (100ASV) · anti-siphon | 3–15 | 40 psi | 200 mesh · 1" PR RBY filter | 150 psi | — |
| Hunter PCZ-101-25 | 1" PGV inline | 0.5–15 | 25 psi | 150 mesh · HFR-100-075 filter-regulator | 120 psi | 34 psi @ 0.5 GPM, 34 psi @ 1 GPM, 34 psi @ 5 GPM, 37 psi @ 10 GPM, 41 psi @ 15 GPM |
| Hunter PCZ-101-40 | 1" PGV inline | 0.5–15 | 40 psi | 150 mesh · HFR-100-075 filter-regulator | 120 psi | 41 psi @ 0.5 GPM, 42 psi @ 1 GPM, 45 psi @ 5 GPM, 52 psi @ 10 GPM, 59 psi @ 15 GPM |
| Hunter ACZ-075-25 | ¾" PGV-ASV anti-siphon · anti-siphon | 0.5–15 | 25 psi | 150 mesh · HFR-075 filter-regulator | 120 psi | 25 psi @ 0.5 GPM, 26 psi @ 1 GPM, 28 psi @ 5 GPM, 30 psi @ 10 GPM, 32 psi @ 15 GPM |
| Hunter ACZ-075-40 | ¾" PGV-ASV anti-siphon · anti-siphon | 0.5–15 | 40 psi | 150 mesh · HFR-075 filter-regulator | 120 psi | 41 psi @ 0.5 GPM, 43 psi @ 1 GPM, 47 psi @ 5 GPM, 52 psi @ 10 GPM, 55 psi @ 15 GPM |
| Hunter ICZ-101-40 | 1" ICV globe (Filter Sentry) | 2–20 | 40 psi | 150 mesh · 1" HY100 wye filter | 150 psi | — |
| Hunter ICZ-101-40-LF | 1" ICV globe, low-flow | 0.5–15 | 40 psi | 150 mesh · HFR-100-075 filter-regulator | 150 psi | — |
| Hunter ICZ-101-25-LF | 1" ICV globe, low-flow | 0.5–15 | 25 psi | 150 mesh · HFR-100-075 filter-regulator | 150 psi | — |
From Rain Bird and Hunter spec sheets, checked Nov 2026.
Drip on 1/2" swing pipe: how far one regulator goes
Robert Kemp's field limit from 18 years of building and upgrading drip in the East Valley. One 40 psi pressure regulator on the drip valve assembly, feeding 1/2" swing pipe, flows up to 3.33 GPM (200 GPH), out to 500 ft of swing pipe. Inside that limit, pressure-compensating emitters put out their rated flow from the first plant to the last.
| PC emitter size | Most emitters per regulator | Flow at that count | Swing pipe, max |
|---|---|---|---|
| 0.5 GPH | 400 | 200 GPH = 3.33 GPM | 500 ft |
| 1 GPH | 200 | 200 GPH = 3.33 GPM | 500 ft |
| 2 GPH | 100 | 200 GPH = 3.33 GPM | 500 ft |
| 4 GPH | 50 | 200 GPH = 3.33 GPM | 500 ft |
Do the math
- Total GPH = emitters × GPH each (add each size separately if mixed).
- GPM = total GPH ÷ 60.
- Regulators needed = total GPH ÷ 200, rounded up. Keep each regulator's swing pipe at 500 ft or less.
Example: 80 emitters at 2 GPH = 160 GPH = 2.67 GPM. One regulator, inside the limit. Example: 150 emitters at 2 GPH = 300 GPH = 5 GPM. Over one regulator: split it into two regulator runs or two valves, or use fewer or smaller emitters if the plants allow.
Built inside these limits with matched PC emitters and new pipe, the design can be guaranteed. Prove it after install: the zone's flow at the meter should be within 10% of the design GPM. Then check that the whole valve's flow fits the drip valve kit and the house's water available.
Nozzles, rotors, bubblers and emitters
Flow at the pressure each product is built for (or the nearest chart row), plus the full range on the manufacturer's chart. Measured flow more than 10% off the chart means something's wrong: a broken head, the wrong nozzle, a leak, or pressure.
Hunter MP Rotator mp
| Model | Arc | At psi | GPM | Radius | Full range on chart |
|---|---|---|---|---|---|
| MP1000 90-210 Maroon | 90° | 40 | 0.21 | 14 ft | 30–55 psi: 0.17–0.27 GPM |
| MP1000 90-210 Maroon | 180° | 40 | 0.42 | 14 ft | 30–55 psi: 0.34–0.51 GPM |
| MP1000 90-210 Maroon | 210° | 40 | 0.49 | 14 ft | 30–55 psi: 0.4–0.59 GPM |
| MP1000 210-270 Light Blue | 210° | 40 | 0.49 | 14 ft | 30–55 psi: 0.4–0.59 GPM |
| MP1000 210-270 Light Blue | 270° | 40 | 0.63 | 14 ft | 30–55 psi: 0.48–0.75 GPM |
| MP1000 360 Olive | 360° | 40 | 0.84 | 14 ft | 30–55 psi: 0.69–1.01 GPM |
| MP2000 90-210 Black | 90° | 40 | 0.43 | 20 ft | 30–55 psi: 0.38–0.48 GPM |
| MP2000 90-210 Black | 180° | 40 | 0.77 | 19 ft | 30–55 psi: 0.64–0.95 GPM |
| MP2000 90-210 Black | 210° | 40 | 0.86 | 19 ft | 30–55 psi: 0.75–1.01 GPM |
| MP2000 210-270 Green | 210° | 40 | 0.86 | 19 ft | 30–55 psi: 0.75–1.01 GPM |
| MP2000 210-270 Green | 270° | 40 | 1.1 | 19 ft | 30–55 psi: 0.95–1.3 GPM |
| MP2000 360 Red | 360° | 40 | 1.48 | 19 ft | 30–55 psi: 1.28–1.74 GPM |
| MP3000 90-210 Blue | 90° | 40 | 0.86 | 30 ft | 30–55 psi: 0.76–1.01 GPM |
| MP3000 90-210 Blue | 180° | 40 | 1.82 | 30 ft | 30–55 psi: 1.58–2.13 GPM |
| MP3000 90-210 Blue | 210° | 40 | 2.12 | 30 ft | 30–55 psi: 1.84–2.49 GPM |
| MP3000 210-270 Yellow | 210° | 40 | 2.12 | 30 ft | 30–55 psi: 1.84–2.49 GPM |
| MP3000 210-270 Yellow | 270° | 40 | 2.73 | 30 ft | 30–55 psi: 2.37–3.22 GPM |
| MP3000 360 Gray | 360° | 40 | 3.64 | 30 ft | 30–55 psi: 3.15–4.27 GPM |
| MP3500 90-210 Light Brown | 90° | 40 | 1.28 | 35 ft | 30–55 psi: 1.13–1.5 GPM |
| MP3500 90-210 Light Brown | 180° | 40 | 2.86 | 35 ft | 30–55 psi: 2.24–3.28 GPM |
| MP3500 90-210 Light Brown | 210° | 40 | 3.29 | 35 ft | 30–55 psi: 2.84–3.94 GPM |
| MP Corner 45-105 Turquoise | 45° | 40 | 0.19 | 14 ft | 30–55 psi: 0.17–0.23 GPM |
| MP Corner 45-105 Turquoise | 90° | 40 | 0.39 | 14 ft | 30–55 psi: 0.34–0.46 GPM |
| MP Corner 45-105 Turquoise | 105° | 40 | 0.45 | 14 ft | 30–55 psi: 0.39–0.53 GPM |
| MP800SR 90-210 Orange/Gray | 90° | 40 | 0.23 | 10 ft | 30–55 psi: 0.17–0.28 GPM |
| MP800SR 90-210 Orange/Gray | 180° | 40 | 0.42 | 10 ft | 30–55 psi: 0.33–0.5 GPM |
| MP800SR 90-210 Orange/Gray | 210° | 40 | 0.43 | 10 ft | 30–55 psi: 0.35–0.56 GPM |
| MP800SR 360 Lime Green/Gray | 360° | 40 | 0.78 | 10 ft | 30–55 psi: 0.66–0.98 GPM |
| MP-LCS-515 Ivory | — | 40 | 0.19 | — | 30–55 psi: 0.17–0.24 GPM |
| MP-RCS-515 Copper | — | 40 | 0.19 | — | 30–55 psi: 0.17–0.24 GPM |
| MP-SS-530 Brown | — | 40 | 0.38 | — | 30–55 psi: 0.33–0.47 GPM |
Rain Bird MPR fixed
| Model | Arc | At psi | GPM | Radius | Full range on chart |
|---|---|---|---|---|---|
| 5Q | 90° | 30 | 0.1 | 5 ft | 15–30 psi: 0.07–0.1 GPM |
| 5H | 180° | 30 | 0.2 | 5 ft | 15–30 psi: 0.14–0.2 GPM |
| 5F | 360° | 30 | 0.41 | 5 ft | 15–30 psi: 0.29–0.41 GPM |
| 8Q | 90° | 30 | 0.26 | 8 ft | 15–30 psi: 0.18–0.26 GPM |
| 8H | 180° | 30 | 0.52 | 8 ft | 15–30 psi: 0.37–0.52 GPM |
| 8F | 360° | 30 | 1.05 | 8 ft | 15–30 psi: 0.74–1.05 GPM |
| 10Q | 90° | 30 | 0.39 | 10 ft | 15–30 psi: 0.29–0.39 GPM |
| 10H | 180° | 30 | 0.79 | 10 ft | 15–30 psi: 0.58–0.79 GPM |
| 10F | 360° | 30 | 1.58 | 10 ft | 15–30 psi: 1.16–1.58 GPM |
| 12Q | 90° | 30 | 0.65 | 12 ft | 15–30 psi: 0.45–0.65 GPM |
| 12H | 180° | 30 | 1.3 | 12 ft | 15–30 psi: 0.9–1.3 GPM |
| 12F | 360° | 30 | 2.6 | 12 ft | 15–30 psi: 1.8–2.6 GPM |
| 15Q | 90° | 30 | 0.92 | 15 ft | 15–30 psi: 0.65–0.92 GPM |
| 15H | 180° | 30 | 1.85 | 15 ft | 15–30 psi: 1.3–1.85 GPM |
| 15F | 360° | 30 | 3.7 | 15 ft | 15–30 psi: 2.6–3.7 GPM |
Rain Bird VAN fixed
| Model | Arc | At psi | GPM | Radius | Full range on chart |
|---|---|---|---|---|---|
| 4-VAN | 90° | 30 | 0.29 | 4 ft | 15–30 psi: 0.21–0.29 GPM |
| 4-VAN | 180° | 30 | 0.45 | 4 ft | 15–30 psi: 0.32–0.45 GPM |
| 4-VAN | 270° | 30 | 0.73 | 4 ft | 15–30 psi: 0.52–0.73 GPM |
| 4-VAN | 330° | 30 | 0.88 | 4 ft | 15–30 psi: 0.62–0.88 GPM |
| 6-VAN | 90° | 30 | 0.37 | 6 ft | 15–30 psi: 0.26–0.37 GPM |
| 6-VAN | 180° | 30 | 0.6 | 6 ft | 15–30 psi: 0.42–0.6 GPM |
| 6-VAN | 270° | 30 | 1.1 | 6 ft | 15–30 psi: 0.79–1.1 GPM |
| 6-VAN | 330° | 30 | 1.2 | 6 ft | 15–30 psi: 0.85–1.2 GPM |
| 8-VAN | 90° | 30 | 0.72 | 8 ft | 15–30 psi: 0.51–0.72 GPM |
| 8-VAN | 180° | 30 | 1.19 | 8 ft | 15–30 psi: 0.84–1.19 GPM |
| 8-VAN | 270° | 30 | 1.55 | 8 ft | 15–30 psi: 1.11–1.55 GPM |
| 8-VAN | 330° | 30 | 1.7 | 8 ft | 15–30 psi: 1.21–1.7 GPM |
| 10-VAN | 90° | 30 | 0.75 | 10 ft | 15–30 psi: 0.48–0.75 GPM |
| 10-VAN | 180° | 30 | 1.45 | 10 ft | 15–30 psi: 0.97–1.45 GPM |
| 10-VAN | 270° | 30 | 2.1 | 10 ft | 15–30 psi: 1.45–2.1 GPM |
| 10-VAN | 360° | 30 | 2.6 | 10 ft | 15–30 psi: 1.93–2.6 GPM |
| 12-VAN | 90° | 30 | 0.59 | 12 ft | 15–30 psi: 0.39–0.59 GPM |
| 12-VAN | 180° | 30 | 1.18 | 12 ft | 15–30 psi: 0.78–1.18 GPM |
| 12-VAN | 270° | 30 | 1.77 | 12 ft | 15–30 psi: 1.17–1.77 GPM |
| 12-VAN | 360° | 30 | 2.36 | 12 ft | 15–30 psi: 1.56–2.36 GPM |
| 15-VAN | 90° | 30 | 0.92 | 15 ft | 15–30 psi: 0.65–0.92 GPM |
| 15-VAN | 180° | 30 | 1.85 | 15 ft | 15–30 psi: 1.3–1.85 GPM |
| 15-VAN | 270° | 30 | 2.78 | 15 ft | 15–30 psi: 1.95–2.78 GPM |
| 15-VAN | 360° | 30 | 3.7 | 15 ft | 15–30 psi: 2.6–3.7 GPM |
| 18-VAN | 90° | 30 | 1.33 | 18 ft | 15–30 psi: 1.05–1.33 GPM |
| 18-VAN | 180° | 30 | 2.66 | 18 ft | 15–30 psi: 2.11–2.66 GPM |
| 18-VAN | 270° | 30 | 3.99 | 18 ft | 15–30 psi: 3.16–3.99 GPM |
| 18-VAN | 360° | 30 | 5.32 | 18 ft | 15–30 psi: 4.21–5.32 GPM |
Rain Bird HE-VAN fixed
| Model | Arc | At psi | GPM | Radius | Full range on chart |
|---|---|---|---|---|---|
| HE-VAN-08 | 90° | 30 | 0.29 | 8 ft | 15–30 psi: 0.21–0.29 GPM |
| HE-VAN-08 | 180° | 30 | 0.59 | 8 ft | 15–30 psi: 0.41–0.59 GPM |
| HE-VAN-08 | 270° | 30 | 0.88 | 8 ft | 15–30 psi: 0.62–0.88 GPM |
| HE-VAN-08 | 360° | 30 | 1.17 | 8 ft | 15–30 psi: 0.83–1.17 GPM |
| HE-VAN-10 | 90° | 30 | 0.45 | 10 ft | 15–30 psi: 0.32–0.45 GPM |
| HE-VAN-10 | 180° | 30 | 0.89 | 10 ft | 15–30 psi: 0.63–0.89 GPM |
| HE-VAN-10 | 270° | 30 | 1.34 | 10 ft | 15–30 psi: 0.95–1.34 GPM |
| HE-VAN-10 | 360° | 30 | 1.78 | 10 ft | 15–30 psi: 1.26–1.78 GPM |
| HE-VAN-12 | 90° | 30 | 0.59 | 12 ft | 15–30 psi: 0.42–0.59 GPM |
| HE-VAN-12 | 180° | 30 | 1.18 | 12 ft | 15–30 psi: 0.84–1.18 GPM |
| HE-VAN-12 | 270° | 30 | 1.77 | 12 ft | 15–30 psi: 1.25–1.77 GPM |
| HE-VAN-12 | 360° | 30 | 2.37 | 12 ft | 15–30 psi: 1.67–2.37 GPM |
| HE-VAN-15 | 90° | 30 | 0.93 | 15 ft | 15–30 psi: 0.65–0.93 GPM |
| HE-VAN-15 | 180° | 30 | 1.85 | 15 ft | 15–30 psi: 1.31–1.85 GPM |
| HE-VAN-15 | 270° | 30 | 2.78 | 15 ft | 15–30 psi: 1.96–2.78 GPM |
| HE-VAN-15 | 360° | 30 | 3.7 | 15 ft | 15–30 psi: 2.62–3.7 GPM |
Rain Bird R-VAN rotary
| Model | Arc | At psi | GPM | Radius | Full range on chart |
|---|---|---|---|---|---|
| R-VAN14 | 90° | 45 | 0.32 | 14 ft | 30–55 psi: 0.28–0.39 GPM |
| R-VAN14 | 180° | 45 | 0.63 | 14 ft | 30–55 psi: 0.56–0.78 GPM |
| R-VAN14 | 210° | 45 | 0.73 | 14 ft | 30–55 psi: 0.65–0.91 GPM |
| R-VAN14 | 270° | 45 | 0.94 | 14 ft | 30–55 psi: 0.84–1.17 GPM |
| R-VAN14-360 | 360° | 45 | 1.27 | 14 ft | 30–55 psi: 1.1–1.45 GPM |
| R-VAN18 | 90° | 45 | 0.5 | 17 ft | 30–55 psi: 0.42–0.58 GPM |
| R-VAN18 | 180° | 45 | 1.01 | 17 ft | 30–55 psi: 0.85–1.09 GPM |
| R-VAN18 | 210° | 45 | 1.17 | 17 ft | 30–55 psi: 0.98–1.26 GPM |
| R-VAN18 | 270° | 45 | 1.51 | 17 ft | 30–55 psi: 1.26–1.62 GPM |
| R-VAN18-360 | 360° | 45 | 1.85 | 17 ft | 30–55 psi: 1.65–2.11 GPM |
| R-VAN24 | 90° | 45 | 0.84 | 23 ft | 30–55 psi: 0.6–0.96 GPM |
| R-VAN24 | 180° | 45 | 1.68 | 23 ft | 30–55 psi: 1.2–1.92 GPM |
| R-VAN24 | 210° | 45 | 1.96 | 23 ft | 30–55 psi: 1.4–2.24 GPM |
| R-VAN24 | 270° | 45 | 2.52 | 23 ft | 30–55 psi: 1.8–2.88 GPM |
| R-VAN24-360 | 360° | 45 | 3.48 | 23 ft | 30–55 psi: 2.35–3.74 GPM |
| R-VAN-LCS | — | 45 | 0.24 | — | 30–55 psi: 0.18–0.28 GPM |
| R-VAN-RCS | — | 45 | 0.24 | — | 30–55 psi: 0.18–0.28 GPM |
| R-VAN-SST | — | 45 | 0.48 | — | 30–55 psi: 0.36–0.56 GPM |
Hunter Pro Adjustable fixed
| Model | Arc | At psi | GPM | Radius | Full range on chart |
|---|---|---|---|---|---|
| 4A Light Green | 45° | 30 | 0.13 | 4 ft | 20–40 psi: 0.1–0.16 GPM |
| 4A Light Green | 90° | 30 | 0.22 | 4 ft | 20–40 psi: 0.19–0.25 GPM |
| 4A Light Green | 120° | 30 | 0.34 | 4 ft | 20–40 psi: 0.28–0.37 GPM |
| 4A Light Green | 180° | 30 | 0.45 | 4 ft | 20–40 psi: 0.34–0.48 GPM |
| 4A Light Green | 240° | 30 | 0.68 | 4 ft | 20–40 psi: 0.58–0.8 GPM |
| 4A Light Green | 270° | 30 | 0.73 | 4 ft | 20–40 psi: 0.62–0.84 GPM |
| 4A Light Green | 360° | 30 | 0.8 | 4 ft | 20–40 psi: 0.66–0.9 GPM |
| 6A Light Blue | 45° | 30 | 0.18 | 6 ft | 20–40 psi: 0.15–0.19 GPM |
| 6A Light Blue | 90° | 30 | 0.37 | 6 ft | 20–40 psi: 0.3–0.4 GPM |
| 6A Light Blue | 120° | 30 | 0.44 | 6 ft | 20–40 psi: 0.37–0.48 GPM |
| 6A Light Blue | 180° | 30 | 0.6 | 6 ft | 20–40 psi: 0.5–0.68 GPM |
| 6A Light Blue | 240° | 30 | 0.88 | 6 ft | 20–40 psi: 0.73–1.02 GPM |
| 6A Light Blue | 270° | 30 | 1.1 | 6 ft | 20–40 psi: 0.88–1.2 GPM |
| 6A Light Blue | 360° | 30 | 1.26 | 6 ft | 20–40 psi: 1.05–1.4 GPM |
| 8A Brown | 45° | 30 | 0.22 | 8 ft | 20–40 psi: 0.18–0.25 GPM |
| 8A Brown | 90° | 30 | 0.44 | 8 ft | 20–40 psi: 0.36–0.5 GPM |
| 8A Brown | 120° | 30 | 0.59 | 8 ft | 20–40 psi: 0.48–0.67 GPM |
| 8A Brown | 180° | 30 | 0.88 | 8 ft | 20–40 psi: 0.72–1 GPM |
| 8A Brown | 240° | 30 | 1.17 | 8 ft | 20–40 psi: 0.96–1.33 GPM |
| 8A Brown | 270° | 30 | 1.32 | 8 ft | 20–40 psi: 1.08–1.5 GPM |
| 8A Brown | 360° | 30 | 1.76 | 8 ft | 20–40 psi: 1.44–2 GPM |
| 10A Red | 45° | 30 | 0.25 | 10 ft | 20–40 psi: 0.2–0.3 GPM |
| 10A Red | 90° | 30 | 0.5 | 10 ft | 20–40 psi: 0.4–0.59 GPM |
| 10A Red | 120° | 30 | 0.67 | 10 ft | 20–40 psi: 0.53–0.79 GPM |
| 10A Red | 180° | 30 | 1 | 10 ft | 20–40 psi: 0.8–1.18 GPM |
| 10A Red | 240° | 30 | 1.33 | 10 ft | 20–40 psi: 1.07–1.57 GPM |
| 10A Red | 270° | 30 | 1.5 | 10 ft | 20–40 psi: 1.2–1.77 GPM |
| 10A Red | 360° | 30 | 2 | 10 ft | 20–40 psi: 1.6–2.36 GPM |
| 12A Green | 45° | 30 | 0.32 | 12 ft | 20–40 psi: 0.25–0.42 GPM |
| 12A Green | 90° | 30 | 0.63 | 12 ft | 20–40 psi: 0.5–0.84 GPM |
| 12A Green | 120° | 30 | 0.84 | 12 ft | 20–40 psi: 0.67–1.12 GPM |
| 12A Green | 180° | 30 | 1.26 | 12 ft | 20–40 psi: 1–1.68 GPM |
| 12A Green | 240° | 30 | 1.68 | 12 ft | 20–40 psi: 1.33–2.24 GPM |
| 12A Green | 270° | 30 | 1.89 | 12 ft | 20–40 psi: 1.5–2.52 GPM |
| 12A Green | 360° | 30 | 2.52 | 12 ft | 20–40 psi: 2–3.36 GPM |
| 15A Black | 45° | 30 | 0.47 | 15 ft | 20–40 psi: 0.39–0.57 GPM |
| 15A Black | 90° | 30 | 0.93 | 15 ft | 20–40 psi: 0.77–1.13 GPM |
| 15A Black | 120° | 30 | 1.24 | 15 ft | 20–40 psi: 1.03–1.51 GPM |
| 15A Black | 180° | 30 | 1.86 | 15 ft | 20–40 psi: 1.54–2.26 GPM |
| 15A Black | 240° | 30 | 2.48 | 15 ft | 20–40 psi: 2.05–3.01 GPM |
| 15A Black | 270° | 30 | 2.79 | 15 ft | 20–40 psi: 2.31–3.39 GPM |
| 15A Black | 360° | 30 | 3.72 | 15 ft | 20–40 psi: 3.08–4.52 GPM |
| 17A Gray | 45° | 30 | 0.58 | 17 ft | 20–40 psi: 0.49–0.69 GPM |
| 17A Gray | 90° | 30 | 1.15 | 17 ft | 20–40 psi: 0.97–1.38 GPM |
| 17A Gray | 120° | 30 | 1.53 | 17 ft | 20–40 psi: 1.29–1.84 GPM |
| 17A Gray | 180° | 30 | 2.3 | 17 ft | 20–40 psi: 1.94–2.76 GPM |
| 17A Gray | 240° | 30 | 3.07 | 17 ft | 20–40 psi: 2.59–3.68 GPM |
| 17A Gray | 270° | 30 | 3.45 | 17 ft | 20–40 psi: 2.91–4.14 GPM |
| 17A Gray | 360° | 30 | 4.6 | 17 ft | 20–40 psi: 3.88–5.52 GPM |
Hunter Pro Fixed fixed
| Model | Arc | At psi | GPM | Radius | Full range on chart |
|---|---|---|---|---|---|
| 8Q Brown | 90° | 30 | 0.24 | 8 ft | 20–40 psi: 0.2–0.28 GPM |
| 8T Brown | 120° | 30 | 0.32 | 8 ft | 20–40 psi: 0.26–0.38 GPM |
| 8H Brown | 180° | 30 | 0.47 | 8 ft | 20–40 psi: 0.38–0.54 GPM |
| 8F Brown | 360° | 30 | 0.97 | 8 ft | 20–40 psi: 0.78–1.13 GPM |
| 10Q Red | 90° | 30 | 0.42 | 10 ft | 20–40 psi: 0.34–0.49 GPM |
| 10T Red | 120° | 30 | 0.57 | 10 ft | 20–40 psi: 0.46–0.66 GPM |
| 10H Red | 180° | 30 | 0.88 | 10 ft | 20–40 psi: 0.7–1.03 GPM |
| 10F Red | 360° | 30 | 1.59 | 10 ft | 20–40 psi: 1.29–1.84 GPM |
| 12Q Green | 90° | 30 | 0.67 | 12 ft | 20–40 psi: 0.54–0.78 GPM |
| 12T Green | 120° | 30 | 0.89 | 12 ft | 20–40 psi: 0.72–1.04 GPM |
| 12H Green | 180° | 30 | 1.3 | 12 ft | 20–40 psi: 1.05–1.52 GPM |
| 12F Green | 360° | 30 | 2.7 | 12 ft | 20–40 psi: 2.17–3.15 GPM |
| 15Q Black | 90° | 30 | 0.97 | 15 ft | 20–40 psi: 0.78–1.14 GPM |
| 15T Black | 120° | 30 | 1.3 | 15 ft | 20–40 psi: 1.04–1.52 GPM |
| 15H Black | 180° | 30 | 1.86 | 15 ft | 20–40 psi: 1.51–2.16 GPM |
| 15F Black | 360° | 30 | 3.75 | 15 ft | 20–40 psi: 3.04–4.36 GPM |
Hunter PGP Ultra rotor
| Model | Arc | At psi | GPM | Radius | Full range on chart |
|---|---|---|---|---|---|
| PGP Ultra 1.5 Blue Blue | — | 45 | 1.5 | 31 ft | 25–65 psi: 1.2–1.9 GPM |
| PGP Ultra 2.0 Blue Blue | — | 45 | 2 | 34 ft | 25–65 psi: 1.4–2.3 GPM |
| PGP Ultra 2.5 Blue Blue | — | 45 | 2.5 | 35 ft | 25–65 psi: 1.7–2.9 GPM |
| PGP Ultra 3.0 Blue Blue | — | 45 | 3 | 38 ft | 25–65 psi: 2.2–3.7 GPM |
| PGP Ultra 4.0 Blue Blue | — | 45 | 4 | 40 ft | 25–65 psi: 3–4.8 GPM |
| PGP Ultra 5.0 Blue Blue | — | 45 | 5 | 42 ft | 25–65 psi: 3.7–6.2 GPM |
| PGP Ultra 6.0 Blue Blue | — | 45 | 6 | 43 ft | 25–65 psi: 4.3–7.3 GPM |
| PGP Ultra 8.0 Blue Blue | — | 45 | 8 | 44 ft | 25–65 psi: 6–9.8 GPM |
Hunter I-20 rotor
| Model | Arc | At psi | GPM | Radius | Full range on chart |
|---|---|---|---|---|---|
| I-20 1.5 Blue Blue | — | 45 | 1.5 | 31 ft | 25–65 psi: 1.2–1.9 GPM |
| I-20 2.0 Blue Blue | — | 45 | 2 | 34 ft | 25–65 psi: 1.4–2.3 GPM |
| I-20 2.5 Blue Blue | — | 45 | 2.5 | 35 ft | 25–65 psi: 1.7–2.9 GPM |
| I-20 3.0 Blue Blue | — | 45 | 3 | 38 ft | 25–65 psi: 2.2–3.7 GPM |
| I-20 4.0 Blue Blue | — | 45 | 4 | 40 ft | 25–65 psi: 3–4.8 GPM |
| I-20 5.0 Blue Blue | — | 45 | 5 | 42 ft | 25–65 psi: 3.7–6.2 GPM |
| I-20 6.0 Blue Blue | — | 45 | 6 | 43 ft | 25–65 psi: 4.3–7.3 GPM |
| I-20 8.0 Blue Blue | — | 45 | 8 | 44 ft | 25–65 psi: 6–9.8 GPM |
Rain Bird 5000 rotor
| Model | Arc | At psi | GPM | Radius | Full range on chart |
|---|---|---|---|---|---|
| 5000 Rain Curtain 1.5 | — | 45 | 1.54 | 35 ft | 25–65 psi: 1.12–1.86 GPM |
| 5000 Rain Curtain 2.0 | — | 45 | 2.07 | 37 ft | 25–65 psi: 1.5–2.52 GPM |
| 5000 Rain Curtain 2.5 | — | 45 | 2.51 | 37 ft | 25–65 psi: 1.81–3.01 GPM |
| 5000 Rain Curtain 3.0 | — | 45 | 3.09 | 40 ft | 25–65 psi: 2.26–3.78 GPM |
| 5000 Rain Curtain 4.0 | — | 45 | 4.01 | 42 ft | 25–65 psi: 2.91–4.83 GPM |
| 5000 Rain Curtain 5.0 | — | 45 | 5.09 | 45 ft | 25–65 psi: 3.72–6.16 GPM |
| 5000 Rain Curtain 6.0 | — | 45 | 6.01 | 46 ft | 25–65 psi: 4.25–7.22 GPM |
| 5000 Rain Curtain 8.0 | — | 45 | 8.03 | 47 ft | 25–65 psi: 5.9–9.63 GPM |
Rain Bird 5000 MPR rotor
| Model | Arc | At psi | GPM | Radius | Full range on chart |
|---|---|---|---|---|---|
| 5000-MPR-25-Q Red | 90° | 45 | 1 | 25 ft | 25–65 psi: 0.74–1.21 GPM |
| 5000-MPR-25-T Red | 120° | 45 | 1.38 | 25 ft | 25–65 psi: 1–1.67 GPM |
| 5000-MPR-25-H Red | 180° | 45 | 1.98 | 25 ft | 25–65 psi: 1.44–2.41 GPM |
| 5000-MPR-25-F Red | 360° | 45 | 3.82 | 25 ft | 25–65 psi: 2.78–4.63 GPM |
| 5000-MPR-30-Q Green | 90° | 45 | 1.4 | 30 ft | 25–65 psi: 1.03–1.69 GPM |
| 5000-MPR-30-T Green | 120° | 45 | 1.85 | 30 ft | 25–65 psi: 1.34–2.24 GPM |
| 5000-MPR-30-H Green | 180° | 45 | 2.96 | 30 ft | 25–65 psi: 2.15–3.6 GPM |
| 5000-MPR-30-F Green | 360° | 45 | 5.78 | 30 ft | 25–65 psi: 4.24–6.92 GPM |
| 5000-MPR-35-Q Beige | 90° | 45 | 1.92 | 35 ft | 25–65 psi: 1.4–2.31 GPM |
| 5000-MPR-35-T Beige | 120° | 45 | 2.46 | 35 ft | 25–65 psi: 1.77–2.99 GPM |
| 5000-MPR-35-H Beige | 180° | 45 | 3.81 | 35 ft | 25–65 psi: 2.75–4.62 GPM |
| 5000-MPR-35-F Beige | 360° | 45 | 7.58 | 35 ft | 25–65 psi: 5.36–9.18 GPM |
Rain Bird 1400 PC Bubbler bubbler
| Model | Arc | At psi | GPM | Radius | Full range on chart |
|---|
Rain Bird 1300A-F Bubbler bubbler
| Model | Arc | At psi | GPM | Radius | Full range on chart |
|---|---|---|---|---|---|
| 1300A-F | 360° | 30 | 1.7 | — | 10–60 psi: 1–2.3 GPM |
Hunter PCB bubbler
| Model | Arc | At psi | GPM | Radius | Full range on chart |
|---|
Rain Bird Xeri-Bug drip
| Model | Flow | Pressure range | PC |
|---|---|---|---|
| XB-05PC Blue | 0.5 GPH | 15–50 psi | Yes |
| XB-10PC Black | 1 GPH | 15–50 psi | Yes |
| XB-20PC Red | 2 GPH | 15–50 psi | Yes |
Rain Bird PC Modules drip
| Model | Flow | Pressure range | PC |
|---|---|---|---|
| PC-05 Light Brown | 5 GPH | 10–50 psi | Yes |
| PC-07 Violet | 7 GPH | 10–50 psi | Yes |
| PC-10 Green | 10 GPH | 10–50 psi | Yes |
| PC-12 Dark Brown | 12 GPH | 10–50 psi | Yes |
| PC-18 White | 18 GPH | 10–50 psi | Yes |
| PC-24 Orange | 24 GPH | 10–50 psi | Yes |
Hunter HE Point Source Emitter drip
| Model | Flow | Pressure range | PC |
|---|---|---|---|
| HE-050-B Blue | 0.5 GPH | 20–50 psi | Yes |
| HE-10-B Black | 1 GPH | 20–50 psi | Yes |
| HE-20-B Red | 2 GPH | 20–50 psi | Yes |
| HE-40-B Tan | 4 GPH | 20–50 psi | Yes |
| HE-60-B Orange | 6 GPH | 20–50 psi | Yes |
From the manufacturers' published performance charts (Hunter, Rain Bird). Used by the MyWaterBudget field app for every flow check.
Connecting a controller to MyWaterBudget
Only Hydrawise and Rachio send live data. Every other controller still works: MyWaterBudget gives the minutes to set each month and the rain alerts.
| Controller | Models | How it works with MyWaterBudget |
|---|---|---|
| Hydrawise Hunter | HPC, Pro-HC, HC, X2 with Wand, ICC2 with Hydrawise | Connects live with an API key. In the Hydrawise app or hydrawise.com: menu (top left) → Account Details → Account Settings → Generate API Key. Copy the whole key. Then paste it in MyWaterBudget where it asks for the Hydrawise API key. |
| Rachio | Rachio 3, Rachio 2, Gen 1 | Connects live with an API key. On a computer, sign in at app.rach.io → your name (top right) → Account Settings → Get API Key. Copy the whole key. Then paste it in MyWaterBudget where it asks for the Rachio API key. |
| Rain Bird Wi-Fi (LNK / LNK2) | ESP-TM2, ESP-Me3, ESP-Me, ARC8 | Virtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand. |
| Orbit B-hyve | B-hyve Smart, B-hyve XR, hose timers | Virtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand. |
| RainMachine | Touch HD, Mini-8, Pro | Virtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand. |
| Wyze Sprinkler | Sprinkler Controller | Virtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand. |
| Weathermatic SmartLink | SmartLink (commercial) | Virtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand. |
| Hunter (not Wi-Fi) | X-Core, X2 without Wand, Pro-C, ICC2 | Virtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand. |
| Rain Bird (not Wi-Fi) | ESP-TM2, ESP-Me, SST | Virtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand. |
| Irritrol | Rain Dial, Total Control, Kwik Dial | Virtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand. |
| Orbit (not Wi-Fi) | Dial and push-button timers | Virtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand. |
| K-Rain | RPS, Pro EX | Virtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand. |
| Other / not sure | Any timer | Virtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand. |
Programming controllers, by make and model
The buttons for the controllers techs see most in Arizona and Oregon: Hunter, Rain Bird, Toro, Irritrol, Weathermatic, K-Rain, Orbit and Rachio. Written from each maker's owner's manual. Minutes come from MyWaterBudget's Water Check, not from guesses.
- Find the model before you touch anything: the label inside the door, or snap the front in the tech chat.
- Following the season, option 1 — seasonal adjust: set every run time with seasonal adjust at 100%, then raise or lower the % as the weather changes. Simple, one setting. A controller left at 50% or 150% makes every run time on the screen wrong, so always know where it sits.
- Following the season, option 2 — change the run times or start times: shorten run times, or drop a start time, when ET falls; add them back as it rises. Fine for a quick fix, but every zone has to be touched.
- Following the season, option 3 — change how often, keep the run times (usually the best way): the roots stay about the same depth all year, so the water one run puts in the root zone stays about the same. ET changes how fast the soil dries out. Set each run time to refill the root zone once, then water more days apart when ET is low and closer together when ET is high. Deep roots, less runoff, and the minutes never change.
- Cycle and soak, when the zone puts water down faster than the soil can take it (clay, a slope, hard-packed soil, a tight spot by a wall): split the run time into shorter cycles with a soak between them. The total minutes stay the same; the runoff stops. Most controllers do this with extra start times in their own program, or a cycle and soak setting on smart controllers.
- One start time runs every zone in that program. Extra start times water the whole program again. Most "it waters twice" calls are a stray start time on program B or C.
- Cold-winter areas (Oregon and the rest of the Northwest): before the first freeze, set the controller to OFF or suspend watering, shut the irrigation supply, and drain or blow out the lines. A Wi-Fi controller can stay powered so it keeps its schedule.
Jump to: Hunter X-Core · Hunter Pro-C (PCC / P2C) · Hunter / Hydrawise HPC, HCC, Pro-HC (Wi-Fi touchscreen) · Rain Bird ESP-TM2 · Rain Bird ESP-ME3 (and ESP-Me) · Toro TMC-212 · Irritrol (Toro) Rain Dial-R (RD-600 / 900 / 1200) · Weathermatic SmartLine (SL800 / SL1600 / SL4800) · K-Rain Pro EX 2.0 (and Pro EX Wi-Fi) · Orbit B-hyve XR (Wi-Fi) · Rachio Rachio 3 (Wi-Fi)
Hunter X-Core
How to spot it: Gray dial controller, small LCD, + / − and arrow buttons, a program button for A/B/C, and a Sensor Bypass slide switch. Indoor model plugs into an outlet; outdoor model has the transformer inside and a locking door.
- Programs: Three programs, A, B and C. Each has its own start times, run times and water days. The program button switches between them.
- Date and time: Dial to CURRENT TIME/DAY. Set year, month, day, then time with + and −; the right arrow moves to the next field.
- Start times: Dial to START TIMES, pick the program. Up to 4 start times per program, in 15-minute steps. To remove one, lower it past 12:00 AM until OFF shows. One start time runs every zone in that program in order.
- Run times: Dial to RUN TIMES. Arrow to each station, set 0 to 4 hours with + and −.
- Water days: Dial to WATER DAYS. Days of the week: + turns a day on, − turns it off. Odd or even: move past SU to ODD/EVEN (the 31st and Feb 29 never water on odd). Interval: from ODD/EVEN, go to interval and set 1–31 days.
- Seasonal adjust: Dial to SEASONAL ADJUSTMENT, set 10% to 150%. Program at 100% first, then adjust.
- Rain off: Dial to SYSTEM OFF, wait for OFF, press + to set 1–7 days, then back to RUN. Dial on SYSTEM OFF for 2 seconds stops everything until it goes back to RUN.
- Run one zone: Dial to MANUAL-ONE STATION, pick the station and time, then turn the dial to RUN to start. The schedule isn't changed.
- Sensor: Slide the Sensor Bypass switch to BYPASS to ignore a Clik rain sensor. A flashing OFF means the sensor is stopping watering, or its jumper was pulled.
- Faults: ERR with a number = a short in that station's wiring or a bad solenoid; fix it, then press any button. P ERR = pump relay or master valve wiring. No AC = no power from the transformer.
- Reset: A full reset erases every program and puts it back to factory settings (hold a button while pressing the reset button for about 8 seconds, until 12:00 AM shows). Check the manual for which button.
Source: Hunter X-Core Owner's Manual (hunterirrigation.com, LIT-397).
Hunter Pro-C (PCC / P2C)
How to spot it: Larger gray dial controller with a PRG button, modular station slots (4-station base, adds 3, 9 or 16 station modules up to 23, or decoders to 32), a Sensor Bypass button, and a reset button on the back of the facepack.
- Programs: Three programs, A, B and C. Press PRG to switch.
- Date and time: Dial to DATE/TIME. + / − sets each value, → moves to the next: year, month, day, AM/PM/24 hr, hours, minutes.
- Start times: Dial to START TIMES, PRG to pick the program, + / − in 15-minute steps, → for the next start. Up to 4 per program. To remove one, go to 12:00 AM and press − once more for OFF. All 4 off = that program doesn't run.
- Run times: Dial to RUN TIMES, PRG for the program, + / − to set, → to the next station. 1 minute to 6 hours.
- Water days: Dial to WATER DAYS. Days: + on, − off. Odd/even: cursor on SU, press → once, then − for EVEN (− again toggles ODD). Interval: → past EVEN, set days between watering, then days until the next watering (1 = tomorrow), then any no-water days.
- Seasonal adjust: Dial to SEASONAL ADJUST, 5% to 300%. Program at 100% first.
- Rain off: Dial to SYSTEM OFF, press + to set 1–99 days off, back to RUN. It counts down at midnight and starts watering again on its own.
- Run one zone: Dial to MANUAL, → to the station, + / − for the time, then dial to RUN. Manual ignores the sensor.
- Run a whole program: Dial on RUN, hold → for 2 seconds. Program A starts after a 2-second pause; PRG picks B or C first.
- Cycle and soak: Hold + while turning the dial to RUN TIMES. Set the cycle (longest run at once), PRG, then the soak (wait before the next cycle).
- Save / restore: Easy Retrieve: hold + and press PRG to save the program; hold − and press PRG to bring it back.
- Sensor: Sensor Bypass button overrides the rain sensor for up to 24 hours. OFF on the display = the sensor stopped watering.
- Faults: ERR + number = short in field wiring or a bad solenoid. P ERR = pump/master valve wiring or a relay drawing too much. SP ERR = electrical noise at the SmartPort. No AC = no power. Shows watering but no water: check wiring with a meter, the solenoid, and that the water is on.
- Reset: Reset button on the back keeps the programming. PRG + reset together erases all watering information.
Source: Hunter Pro-C (P2C) Owner's Manual (hunterirrigation.com).
Hunter / Hydrawise HPC, HCC, Pro-HC (Wi-Fi touchscreen)
How to spot it: Color touchscreen with Home, Zones, Settings and Status. Programmed in the Hydrawise app or hydrawise.com. HPC is the Pro-C body with a Wi-Fi facepack (4–32 zones).
- Where to program: In the Hydrawise app or website: Zones and Schedules. Run length and frequency per zone; Add Watering Time for start times and days.
- Run one zone (at the controller): Home → Zones → pick the zone → Run Time (optional) → Run Now. The button turns to Stop while it runs.
- Run one zone (app): Tap the zone, then the play button, pick normal or a custom time, Run now. "Run all zones" is under the gear menu.
- Suspend / winterize: Gear above the zones → Suspend all zones → pick the dates → suspend. Remove suspension to start early. It resumes on its own after the date.
- Weather adjustment: Predictive Watering uses Watering Triggers on the dashboard: skip below a forecast temperature, water less when cool, more when hot, skip for rain chance, wind, or rain in the last 24 hours or 7 days.
- Offline: If it's off the internet more than 24 hours it goes offline and emails the account. Offline it keeps watering its last schedule. Offline seasonal adjust: Home → Settings → Offline Status → Seasonal Adjust (Wi-Fi must be turned off to change offline settings).
- Alerts: Wiring short (high current) = solenoid drawing too much: bad wire or valve. Broken wire = no current when the zone runs. High / low water usage = flow off from the last run (leak, or a blockage). Water with no zone running = a leak or someone using water.
- Serial number: Back of the controller, or Home → Status → Controller Status (8 characters, a–f and 0–9).
- Factory reset: Home → Settings → Config → Factory Default → Erase Config.
Source: Hydrawise App Owner's Manual (Hunter Industries).
Rain Bird ESP-TM2
How to spot it: Rain Bird gray dial controller, 4 to 12 stations (no modules), Back/Next and + / − buttons, a Program Select button, works with the LNK Wi-Fi module.
- Programs: Three programs, A, B and C. Program Select switches between them.
- Date and time: Dial to DATE/TIME. Back/Next picks the setting, + / − changes it (hold to go fast).
- Start times: Dial to START TIMES, Program Select for the program, Back/Next to the start, + / − to set. Watch AM/PM. 4 per program.
- Run times: Dial to RUN TIMES, pick the program, Back/Next to the station, + / −. 1 minute to 6 hours.
- Water days: Dial to RUN DAYS, pick the program, + / − sets each day on or off. Going past Sunday opens Cyclic (every X days): set the day cycle, then days remaining. Odd/even uses a two-button hold on that screen — see the manual.
- Seasonal adjust: Dial to SEASONAL ADJUST, 5% to 200% for all programs; press Program Select first to change just one program.
- Rain delay: From AUTO RUN, a press-and-hold opens Delay Watering; set up to 14 days with + / −. Back to 0 cancels. (Button name: see the manual.)
- Rain sensor: Dial to SENSOR: ACTIVE obeys the sensor, BYPASS ignores it. Normally-closed sensors only; pull the yellow jumper only when a sensor is wired in.
- Run one zone: Dial to MANUAL STATION, pick the station with Back/Next, set the time, then hold to start or turn the dial to AUTO RUN.
- Stop a manual run: Dial to OFF for 3 seconds.
- Faults: A short on a station or the master valve shows a short message. Fix the wiring, then test the valve to clear it. Blank or frozen screen: unplug 2 minutes, or press RESET.
- Reset: RESET button (paper clip) restarts and keeps the schedule. Reset to Factory Defaults (a Special Feature) erases every schedule.
Source: Rain Bird ESP-TM2 Controller User Manual (rainbird.com).
Rain Bird ESP-ME3 (and ESP-Me)
How to spot it: Rain Bird modular dial controller: 4-station base, 3- and 6-station modules up to 22 stations, ALARM light, Hold to Start button, works with the LNK Wi-Fi module.
- Programs: Four programs, A–D. Program Select cycles through them.
- Date and time: Dial to Date/Time. Back/Next picks, + / − changes.
- Start times: Dial to Start Times, Program Select, Back/Next to the start, + / −. Up to 6 per program. To remove one, go to 12:00 AM, then one more press for OFF. One start time runs every station in the program; extra starts water again.
- Run times: Dial to Run Times, pick the program, Back/Next to the station, + / −. 1 minute to 6 hours. Zero = the station isn't in that program.
- Water days: Dial to Water Days, pick the program, + / − sets each day. Past SUN is Cyclic: set the day cycle, then days remaining. Odd/even: a two-button hold on the Water Days screen.
- Seasonal adjust: Dial to Seasonal Adjust, 5% to 200%. Program Select first to adjust one program only.
- Delay watering: From AUTO, press and hold the delay button, set days remaining up to 14. 0 cancels.
- Rain sensor: Dial to Weather Sensors: SENS ON or SENS OFF. Manual watering runs even with the sensor on.
- Run one zone: Dial to Manual Watering, Back/Next to the station, set the time, press Hold to Start, then dial to AUTO. Repeat to queue more.
- Run a program: Dial on AUTO, Program Select, press Hold to Start.
- Test all: Dial to Manual Watering, set a time, Hold to Start, then AUTO once STARTED shows.
- Stop: Dial to OFF for 3 seconds.
- Alarms: ALARM light, read with the dial on AUTO. Blinking = programming (NO START TIMES, NO RUN TIMES, NO WATER DAYS). Solid = STATION X WIRE SHORTED or MASTER VALVE SHORTED. A shorted station is skipped and retried next run; a good run clears it.
- Reset: Reset button (paper clip) reboots and keeps the schedules. Factory reset on the ESP-Me: dial to Seasonal Adjust, hold left and right arrows together 3 seconds until CLEARED, then back to AUTO RUN — this erases the programming.
Source: Rain Bird ESP-ME3 Advanced User Manual; Rain Bird support (ESP-Me factory reset).
Toro TMC-212
How to spot it: Toro dial controller, 2 to 12 stations with 2-station modules, a PROGRAMS slide switch (A/B/C), +/ON, −/OFF, NEXT and MANUAL START buttons, rain sensor switches inside.
- Programs: Three programs; the PROGRAMS switch picks A, B or C.
- Date and time: Dial to CURRENT TIME/DAY. +/ON or −/OFF changes, NEXT moves through minutes, year, month, day. Back to RUN.
- Start times: Dial to START TIMES, set the PROGRAMS switch, NEXT to start 1–4, + / − to set. Press + and − together for OFF.
- Run times: Dial to STATION TIMES, set the program, NEXT to the station, + / −. OFF, or 1 minute to 4 hours.
- Water days: Dial to WATERING DAYS: Calendar (pick weekdays), Interval (1–7 days and a start day), Odd/Even (odd skips the 31st and Feb 29), or OFF (program off, settings kept). Day exclusion (dE) works with Interval or Odd/Even.
- Season adjust: Dial to SEASON ADJUST, 10% to 200% in 10% steps. Over 100% it splits the longer run into back-to-back cycles.
- Rain delay: Dial to RAIN DELAY, 1–7 days, back to RUN. Cancel: dial to OFF about 5 seconds, then RUN.
- Rain sensor: Sensor switch ENB = the sensor can stop watering; DIS = bypass. Match the NO/NC switch to the sensor.
- Run a program: Dial on RUN, set the PROGRAMS switch, press MANUAL START twice.
- Run some zones: Dial on RUN, MANUAL START once, + to include a station, − to skip it, MANUAL START to begin. NEXT skips the running station.
- Stop: Dial to OFF about 2 seconds, then RUN.
- Faults: FUSE with a station number = that station is overloaded (shorted splice or bad solenoid) and is skipped. FUSE with MV = pump/master valve circuit overloaded; automatic watering stops. Blank display: transformer or breaker.
- Clear memory: One program: dial to SEASON ADJUST, set the program, NEXT once (CL flashes), hold −/OFF 5 seconds. All programs: dial to OFF, NEXT, hold −/OFF 5 seconds.
Source: Toro TMC-212 User's Guide (373-0402).
Irritrol (Toro) Rain Dial-R (RD-600 / 900 / 1200)
How to spot it: Irritrol dial controller, 6, 9 or 12 stations, a Function switch (Run / Set Programs / Off-Stop), a Program switch (A/B/C), + / − buttons, Manual and Semi-Auto buttons, takes a 9V battery.
- How it works: Function switch to Set Programs to make changes, back to Run when done. The dial picks the setting; + / − change it; Manual acts as "next."
- Time and day: Dial to Current Time and set it (watch AM/PM), dial to Today and set the day, back to Current Time, Function to Run. A flashing colon means it has AC power.
- Start times: Program switch to A, B or C. Dial to Start Time 1, 2 or 3 and set it. Up to 3 per program. OFF sits between 11:59 and 12:00.
- Run times: Dial to the station number and set 1–59 minutes or 1.0–5.9 hours.
- Water days: Dial to each weekday and turn it on or off. Skip Days (every 1–31 days): dial to Skip Days/Special Functions. Odd/even is in the same spot (press Manual 7 times). A program uses Skip Days or Odd/Even, not both.
- Water budget: Dial to Skip Days/Special Functions, pick the program, press Manual twice to show 100%, then 10% to 200% in 10% steps. A monthly budget can override it.
- Rain delay: In Skip Days/Special Functions, press Manual until rd0 shows, set 1–9 days. 0 cancels.
- Run one zone: Function to Run, dial to the station, set a time, press Manual.
- Run a program: Function to Run, dial to Current Time, pick the program, press Semi-Auto. Manual moves to the next station.
- Test all zones: Dial to Skip Days/Special Functions, press Manual once for Test Run, set 1–10 minutes, press Semi-Auto.
- Stop: Move the Function switch to Off/Stop briefly.
- Sensor: Sensor switch Active with a sensor, Bypass without one. With no sensor, the jumper must stay in and the switch on Bypass. SEn on the display = the sensor is holding watering.
- Faults: FUS with a station number = a short or too much current on that station; it gets skipped. Fix it, then press any button. Blank display: transformer, the 2 A fuse, or power. Flashing wrong time: lost power with no battery — put in a 9V and reset the time.
- Clear: One program: in Skip Days/Special Functions press Manual until CLr, then + / − to CL? and End. All programs: dial to Start Time 3 and press Manual repeatedly until ALL, then OFF flashes; back to Current Time (shows 12:00 AM).
Source: Irritrol Rain Dial-R User's Guide (373-0538).
Weathermatic SmartLine (SL800 / SL1600 / SL4800)
How to spot it: Weathermatic dial controller with PGM, NEXT/BACK, UP/DOWN and START MANUAL PROGRAM buttons, a RAIN/FREEZE button, and status lights. SL800 4–8 zones, SL1600 4–16, SL4800 12–48. Optional SLW on-site weather sensor for SMART mode.
- Model: Advanced Menu → ABOUT → MODEL.
- Programs: Four programs, A–D; PGM picks the program.
- Two modes: BASIC uses the run times you set. SMART (needs the SLW weather sensor) sets run times and run/soak itself from the zone settings. BASIC must be programmed first.
- Start times: 10-minute steps. Three start slots show by default (Advanced Menu NUM STRT allows 1–8). Unused = OFF, between 11:50 PM and midnight.
- Run times: OFF to 59 minutes in 1-minute steps, then 1 hour to 9:55 in 5-minute steps. Set unused zones to OFF so a pump never runs with no flow.
- Water days: DAYS (pick weekdays), EVEN, ODD (skips the 31st and Feb 29), or INTERVAL (every 1–30 days with a start day). OMIT settings can block a time window, weekdays or specific dates.
- Seasonal adjust: Seasonal % Adjust: 0% to 300% in 5% steps, set by month.
- Rain delay: RAIN DLY stops all programs 1–14 days. After rain the SLW holds watering 48 hours by default (0–99).
- System off: Dial to SYSTEM OFF. Programs are kept; the mode light turns red.
- Manual: Dial on RUN, press START MANUAL PROGRAM (PGM first to choose the program). Manual Zone runs one zone for a set time and ignores days and rain. Manual Test runs every zone with a run time, 10 seconds to 10 minutes, and finds opens and shorts.
- Sensor: RAIN/FREEZE button bypasses the sensors (green OFF light). Red rain/freeze light = watering blocked. Orange mode light = a pause (soak, delay or omit).
- SMART setup: Enter ZIP code. For each zone: sprinkler type (or precip rate), plant type, soil type, slope; MORE/LESS fine-tunes −50% to +25%. Press WATERING MODE: green SMART light = good; flashing red = something missing (sensor, ZIP, date/time or sprinkler type).
- Faults: Advanced Menu → FAULTS: ZONE XX OPEN, ZONE XX SHORT, MV OPEN/SHORT, INSUFFICIENT WATERING OPPORTUNITY, NO RECENT CONTACT WITH WEATHER SENSOR. Clearing a fault doesn't fix it — it comes back next run. No AC = no power.
- Clear: CLR PGM clears one program; CLR ALL clears all four and most Advanced settings.
Source: Weathermatic SmartLine Owner's Manual.
K-Rain Pro EX 2.0 (and Pro EX Wi-Fi)
How to spot it: K-Rain dial controller with a big backlit display, 4-station base module expanding to 16 with 4-station modules, PROGRAM SELECT and RAIN SENSOR SELECT buttons, MANUAL START/NEXT, BACK/NEXT and UP/DOWN. Wi-Fi version adds a hub and the K-Rain app.
- Programs: Three programs, A, B, C; PROGRAM SELECT picks one before you program it.
- Date and time: Dial to SET TIME/DATE, UP/DOWN changes, NEXT moves through hour, minute, day, month, year. BACK + NEXT together toggles 12/24 hour.
- Start times: PROGRAM SELECT, dial to SET PROGRAM START TIMES, UP/DOWN in 15-minute steps, NEXT to the next. Up to 4 per program. Set OFF to remove.
- Run times: Dial to SET STATION RUN TIMES, UP/DOWN and NEXT. 1 second to 6 hours; OFF for none.
- Water days: Dial to SET WATERING DAYS: UP/DOWN turns each day on or off. BACK + NEXT together steps to ODD, EVEN, then CYCLE (set days remaining, then a 1–31 day cycle).
- Water budget: Dial to SPECIAL FEATURES: 10% to 200% in 10% steps (a 10-minute zone at 80% runs 8 minutes).
- Rain sensor: RAIN SENSOR SELECT button: obey or bypass. BYPASSED shows top left when bypassed. With the sensor ON, a sensor or jumper must be wired in or nothing runs.
- Run one zone: Dial to RUN SINGLE STATION, NEXT, UP/DOWN to the station, MANUAL START. A zone with zero run time won't start.
- Run a program: Pick the program, dial to AUTO or RUN PROGRAM, press MANUAL START/NEXT.
- Test all: Dial to SYSTEM TEST, pick TEST, MANUAL START (2 minutes a zone by default).
- Stop: Dial to OFF for 3 seconds. If it was turned off from the app it shows BYPASS WiFi: dial to OFF then back to AUTO.
- Review: Dial to PROGRAM DISPLAY to see a program's days, starts and run times.
- Alarms: ERROR/ALARM light: sensor stopping watering, a shorted valve, or a programming error. Shorts and opens flash the station and beep. Dial to OFF briefly then AUTO to clear for now; it resets itself after the repair. Open-circuit detection can be turned off in SPECIAL FEATURES.
- Clear / reset: SPECIAL FEATURES → NEXT to CLEAR → UP/DOWN to CLEAR* → NEXT: back to factory (all zones, every day, 10 minutes). RESET on the back of the panel keeps the programming.
Source: K-Rain Pro EX 2.0 Installation, Programming and Operation Manual.
Orbit B-hyve XR (Wi-Fi)
How to spot it: Small white Orbit timer with one button and a light ring, programmed only in the B-hyve app. 8 or 16 zones.
- Where to program: All schedules are in the B-hyve app (start time, run time, how often, budget), or turn on Smart Watering. Schedules are stored on the timer too, so it keeps watering if Wi-Fi drops.
- Rain delay: Set in the app. The timer then blinks yellow and shows DELAY.
- At the timer: One button: hold it to reach MANUAL → WATER ALL ZONES (10 minutes each by default), quick presses step to WATER A ZONE or WATER A PROGRAM. A quick press skips the running zone; hold 2–5 seconds cancels all watering; hold 10 seconds = on/off; 5 quick presses = hard reset. (Read off Orbit's quick start; check it on the unit.)
- Lights: Blinking blue = ready to pair. Solid white = on Wi-Fi and paired. Blinking yellow = rain delay on.
Source: Orbit B-hyve XR Quick Start Guide.
Rachio Rachio 3 (Wi-Fi)
How to spot it: White square controller with a light bar and on-unit Run, Pause and Skip buttons. 8 or 16 zones. Programmed in the Rachio app.
- Where to program: Everything is in the Rachio app or app.rach.io: schedules, zones and zone settings.
- Run a zone: In the app, pick the zone (or schedule) and tap Quick Run.
- Weather: Weather Intelligence skips for rain, freeze and wind, and Seasonal Shift changes run times through the year from past weather. Thresholds are under Weather Intelligence in the More tab.
- Offline: Off Wi-Fi for 24 hours = offline. Unplug it and plug it back in; restart the router if needed. After a power loss it picks up where it left off.
Source: Rachio support (Rachio 3 FAQ, Weather Intelligence Plus).
Troubleshooting controllers, valves and wiring
Controller wiring is 24-volt, but the controller plugs into house power. Turn the power off before you open it. If you're not sure, call a pro.
A zone won't come on
- Controller first. Check the display is on; no rain delay, rain sensor or "sensor off" is showing; seasonal adjust or water budget isn't at 0%; and that program has a start time and run time.
- Run the zone by hand from the controller. Then open the valve by hand: on most Hunter and Rain Bird valves, turn the solenoid about a half turn counterclockwise (or open the bleed screw). Snug it back clockwise to close.
- Opens by hand, not from the controller = an electrical problem. Go to the meter checks below.
- Won't open by hand either = a water problem. Check the shut-off and backflow are open, the flow control isn't screwed down, and look for debris or a torn diaphragm.
Meter checks (controller off for resistance, on for voltage)
| Check | Normal | What it means if not |
|---|---|---|
| Wall power into the controller | 105–129 VAC | Outside that: electrician. Not a sprinkler fix. |
| Transformer output | 24–28 VAC | Outside that: bad transformer. |
| Station terminal to COM, zone running | 24–28 VAC | Low or none on one station: controller output. Fine at the clock but low at the valve: wire or splice. |
| Station to COM, power off, wires on | 20–60 ohms | Under 20: short, crossed wires, or two valves on one station (more valves read lower). Over 60: broken wire, bad splice or bad solenoid. |
| Solenoid alone, wires off at the valve | Rain Bird: 20–60 ohms (G4 solenoid 30–39 nominal). Hunter AC: about 25–35 ohms | 0 or "open": replace the solenoid. Good solenoid but bad reading from the clock: the field wire. |
| Field wires alone, solenoid off | About 5 ohms or less (shorted at the valve end) | High: broken wire or bad splice between clock and valve. |
Battery controllers use DC-latching solenoids, not 24 VAC. Hunter's DC-latching solenoid reads about 4.8 ohms and runs on 6–9 VDC. Don't mix AC and DC solenoids.
A valve won't shut off or keeps weeping
- Solenoid left open a quarter turn, or the bleed screw open. Snug them.
- Debris on the diaphragm seat or a torn diaphragm. Shut the water off, open the bonnet, clean or replace.
- Too little pressure to seat it. Hunter valves need at least 20 psi to close.
- Low head drainage after shut-off is not the valve: that's the pipe draining out the lowest head. A check-valve body fixes it.
- Meter moving with every zone and the house off = a leak. Treat it as a leak alert, not a wait-and-see.
Weak heads, short throw, dry spots
- Read static at the hose bib, then running pressure on the zone. A drop of 35+ psi is a flag.
- Check the zone's GPM against "Water available" above. More than the house can supply = split the zone or lower its flow.
- Check pipe loss: psi at the furthest head ≈ running psi − valve loss (MyWaterBudget uses 5 psi) − pipe friction (tables above) − 0.433 psi per foot uphill.
- Spray wants 25–35 psi at the head (best 30), MP Rotator / R-VAN 35–45 (best 40), rotors 40–55 (best 45).
Drip zone not doing its job
- Clean the filter screen. Then check the regulator: no regulator on drip is a flag.
- Flush the end caps. Count emitters per plant against the plant's need. Add emitters, not minutes.
- Non-PC emitters on a long run: the first plants get more than the last. Swap to pressure-compensating.
Wi-Fi controller offline
- Power at the outlet and the controller display first. Then the home router: new router, new password or a 5 GHz-only network are the usual causes.
- An offline smart controller still waters its last schedule, but it stops skipping for rain and stops sending alerts.
Voltage and resistance ranges: Rain Bird multimeter troubleshooting guides and G4 solenoid guide; Hunter support pages (valve not opening, valve not closing, solenoids). Field steps: Robert Kemp, 18 years running an East Valley irrigation company.