Irrigation reference

The numbers a tech uses in the yard: how much water the house can run, what the pipe loses, what each nozzle and emitter puts out, and how to find an electrical or valve problem. Same data the MyWaterBudget apps use. Updated Nov 21, 2026.

Water available: the most one zone should pull

Put a gauge on the hose bib nearest the meter with nothing running (static pressure). Read the meter size off the meter. Find the service line size: wrap a string around the pipe from the meter to the house once and measure it. Copper: 2¾" = ¾", 3½" = 1", 4⅜" = 1¼". PVC or galvanized: 3¼" = ¾", 4⅛" = 1", 5¼" = 1¼".

MeterService line30 psi40 psi50 psi60 psi70 psi80 psi
⅝"½"245677
⅝"¾"46881012
⅝"1"478101315
¾"¾"46891012
¾"1"5710141720
¾"1¼"51217202222
1"¾"47891212
1"1"5814182020
1"1¼"51424263034

Max GPM per zone, by static pressure. Method and chart: Hunter Industries, Residential Sprinkler System Design Guide (LIT-226), "Determine System Design Capacity." The chart is for 100 ft of thick-walled PVC service line. Copper service line: take off 2 GPM. Galvanized: take off 5 GPM. Approximate working pressure at the heads for 30 / 40 / 50 / 60 / 70 / 80 psi static: 25 / 30 / 35 / 45 / 50 / 55 psi. Under 30 psi static, sprays won't perform: drip and MP Rotators only, or a booster. Over 80 psi static needs a pressure regulator (PRV) at the house. Use the calculator on the Resources page for your own house.

Pipe sizes and friction loss

Keep water under 5 feet per second. Faster than that: water hammer, fittings that work loose, and pressure lost before the heads.

SizePipeInside dia.Max GPM (5 ft/s)
½"Sch 400.622"4.7
¾"Sch 400.824"8.3
1"Sch 401.049"13.5
1¼"Sch 401.380"23.3
1½"Sch 401.610"31.7
2"Sch 402.067"52.3
¾"Class 2000.930"10.6
1"Class 2001.189"17.3
1¼"Class 2001.502"27.6
1½"Class 2001.720"36.2
2"Class 2002.149"56.5
½"Drip tubing0.600"4.4
¼"Drip micro tubing0.170"0.4

Max GPM = 2.448 × 5 ft/s × inside diameter². Inside diameters are typical; check the pipe you buy.

Friction loss, psi per 100 ft of pipe

Computed with the Hazen-Williams formula (C = 150 for PVC, 140 for poly). * = over 5 ft/s: size up. — = far too fast for that size. For a run shorter or longer than 100 ft, scale it: 50 ft = half the number.

PVC Sch 40 C = 150

GPM½"
0.622" ID
¾"
0.824" ID
1"
1.049" ID
1¼"
1.380" ID
1½"
1.610" ID
2"
2.067" ID
10.430.110.03<0.01<0.01<0.01
21.550.390.120.030.02<0.01
33.280.840.260.070.03<0.01
45.591.420.440.120.050.02
58.45*2.150.660.170.080.02
611.8*3.010.930.250.120.03
8—5.141.590.420.200.06
10—7.76*2.400.630.300.09
12—10.9*3.360.890.420.12
15——5.08*1.340.630.19
20——8.66*2.281.080.32
25———3.45*1.630.48
30———4.83*2.280.68

PVC Class 200 (SDR 21) C = 150

GPM¾"
0.930" ID
1"
1.189" ID
1¼"
1.502" ID
1½"
1.720" ID
2"
2.149" ID
10.060.02<0.01<0.01<0.01
20.220.070.020.01<0.01
30.460.140.040.02<0.01
40.790.240.080.040.01
51.190.360.120.060.02
61.670.510.160.080.03
82.850.860.280.140.05
104.311.300.420.220.07
126.04*1.830.590.300.10
159.13*2.760.890.460.16
20—4.71*1.510.780.26
25—7.12*2.281.180.40
30——3.20*1.650.56

PVC Class 315 (SDR 13.5) C = 150

GPM½"
0.716" ID
¾"
0.894" ID
1"
1.120" ID
1¼"
1.414" ID
1½"
1.619" ID
2"
2.023" ID
10.220.070.02<0.01<0.01<0.01
20.780.270.090.030.01<0.01
31.650.560.190.060.030.01
42.820.960.320.100.050.02
54.261.450.480.160.080.03
65.972.030.680.220.110.04
810.2*3.451.150.370.190.06
10—5.22*1.740.560.290.10
12—7.32*2.440.790.410.14
15——3.701.190.620.21
20——6.30*2.031.050.35
25———3.06*1.580.54
30———4.29*2.220.75

Poly (SIDR, ID-controlled) C = 140

GPM½"
0.622" ID
¾"
0.824" ID
1"
1.049" ID
1¼"
1.380" ID
10.490.120.040.01
21.760.450.140.04
33.730.950.290.08
46.351.620.500.13
59.60*2.440.760.20
613.5*3.431.060.28
8—5.841.800.47
10—8.82*2.730.72
12—12.4*3.821.01
15——5.78*1.52
20——9.84*2.59
25———3.92*
30———5.49*

Psi at the furthest head ≈ running psi − valve loss (MyWaterBudget uses 5 psi) − pipe friction − 0.433 psi for every foot of rise. Fittings add loss too; long runs with many fittings lose more than the straight-pipe number. Class 315 inside diameters are figured from the standard outside diameter at SDR 13.5.

Drip valve kits

Valve + filter + pressure regulator in one kit. Pick the kit whose flow range covers the zone, with enough pressure coming in to hold its rating.

KitValveGPM rangeRegulates toFilterInlet maxInlet needed at flow
Rain Bird XCZ-075-PRF¾" low-flow inline (LFV075)0.2–530 psi200 mesh · ¾" PR RBY filter150 psi34.4 psi @ 0.2 GPM, 36.1 psi @ 1 GPM, 38.1 psi @ 3 GPM, 43.4 psi @ 5 GPM
Rain Bird XCZLF-100-PRF1" low-flow inline (LFV100)0.2–1040 psi200 mesh · 1" PR RBY filter150 psi44.4 psi @ 0.2 GPM, 44.4 psi @ 1 GPM, 45 psi @ 3 GPM, 46.2 psi @ 5 GPM, 52.2 psi @ 10 GPM
Rain Bird XCZ-100-PRF1" DV inline (100DV)3–1540 psi200 mesh · 1" PR RBY filter150 psi42.9 psi @ 3 GPM, 44.1 psi @ 5 GPM, 46.9 psi @ 8 GPM, 48.5 psi @ 10 GPM, 55.5 psi @ 15 GPM
Rain Bird XACZ-075-PRF¾" anti-siphon low-flow (ASVLFV075) · anti-siphon0.2–530 psi200 mesh · ¾" PR RBY filter150 psi—
Rain Bird XACZ-100-PRF1" anti-siphon (100ASV) · anti-siphon3–1540 psi200 mesh · 1" PR RBY filter150 psi—
Hunter PCZ-101-251" PGV inline0.5–1525 psi150 mesh · HFR-100-075 filter-regulator120 psi34 psi @ 0.5 GPM, 34 psi @ 1 GPM, 34 psi @ 5 GPM, 37 psi @ 10 GPM, 41 psi @ 15 GPM
Hunter PCZ-101-401" PGV inline0.5–1540 psi150 mesh · HFR-100-075 filter-regulator120 psi41 psi @ 0.5 GPM, 42 psi @ 1 GPM, 45 psi @ 5 GPM, 52 psi @ 10 GPM, 59 psi @ 15 GPM
Hunter ACZ-075-25¾" PGV-ASV anti-siphon · anti-siphon0.5–1525 psi150 mesh · HFR-075 filter-regulator120 psi25 psi @ 0.5 GPM, 26 psi @ 1 GPM, 28 psi @ 5 GPM, 30 psi @ 10 GPM, 32 psi @ 15 GPM
Hunter ACZ-075-40¾" PGV-ASV anti-siphon · anti-siphon0.5–1540 psi150 mesh · HFR-075 filter-regulator120 psi41 psi @ 0.5 GPM, 43 psi @ 1 GPM, 47 psi @ 5 GPM, 52 psi @ 10 GPM, 55 psi @ 15 GPM
Hunter ICZ-101-401" ICV globe (Filter Sentry)2–2040 psi150 mesh · 1" HY100 wye filter150 psi—
Hunter ICZ-101-40-LF1" ICV globe, low-flow0.5–1540 psi150 mesh · HFR-100-075 filter-regulator150 psi—
Hunter ICZ-101-25-LF1" ICV globe, low-flow0.5–1525 psi150 mesh · HFR-100-075 filter-regulator150 psi—

From Rain Bird and Hunter spec sheets, checked Nov 2026.

Drip on 1/2" swing pipe: how far one regulator goes

Robert Kemp's field limit from 18 years of building and upgrading drip in the East Valley. One 40 psi pressure regulator on the drip valve assembly, feeding 1/2" swing pipe, flows up to 3.33 GPM (200 GPH), out to 500 ft of swing pipe. Inside that limit, pressure-compensating emitters put out their rated flow from the first plant to the last.

PC emitter sizeMost emitters per regulatorFlow at that countSwing pipe, max
0.5 GPH400200 GPH = 3.33 GPM500 ft
1 GPH200200 GPH = 3.33 GPM500 ft
2 GPH100200 GPH = 3.33 GPM500 ft
4 GPH50200 GPH = 3.33 GPM500 ft

Do the math

  1. Total GPH = emitters × GPH each (add each size separately if mixed).
  2. GPM = total GPH ÷ 60.
  3. Regulators needed = total GPH ÷ 200, rounded up. Keep each regulator's swing pipe at 500 ft or less.

Example: 80 emitters at 2 GPH = 160 GPH = 2.67 GPM. One regulator, inside the limit. Example: 150 emitters at 2 GPH = 300 GPH = 5 GPM. Over one regulator: split it into two regulator runs or two valves, or use fewer or smaller emitters if the plants allow.

Built inside these limits with matched PC emitters and new pipe, the design can be guaranteed. Prove it after install: the zone's flow at the meter should be within 10% of the design GPM. Then check that the whole valve's flow fits the drip valve kit and the house's water available.

Nozzles, rotors, bubblers and emitters

Flow at the pressure each product is built for (or the nearest chart row), plus the full range on the manufacturer's chart. Measured flow more than 10% off the chart means something's wrong: a broken head, the wrong nozzle, a leak, or pressure.

Hunter MP Rotator mp

ModelArcAt psiGPMRadiusFull range on chart
MP1000 90-210 Maroon90°400.2114 ft30–55 psi: 0.17–0.27 GPM
MP1000 90-210 Maroon180°400.4214 ft30–55 psi: 0.34–0.51 GPM
MP1000 90-210 Maroon210°400.4914 ft30–55 psi: 0.4–0.59 GPM
MP1000 210-270 Light Blue210°400.4914 ft30–55 psi: 0.4–0.59 GPM
MP1000 210-270 Light Blue270°400.6314 ft30–55 psi: 0.48–0.75 GPM
MP1000 360 Olive360°400.8414 ft30–55 psi: 0.69–1.01 GPM
MP2000 90-210 Black90°400.4320 ft30–55 psi: 0.38–0.48 GPM
MP2000 90-210 Black180°400.7719 ft30–55 psi: 0.64–0.95 GPM
MP2000 90-210 Black210°400.8619 ft30–55 psi: 0.75–1.01 GPM
MP2000 210-270 Green210°400.8619 ft30–55 psi: 0.75–1.01 GPM
MP2000 210-270 Green270°401.119 ft30–55 psi: 0.95–1.3 GPM
MP2000 360 Red360°401.4819 ft30–55 psi: 1.28–1.74 GPM
MP3000 90-210 Blue90°400.8630 ft30–55 psi: 0.76–1.01 GPM
MP3000 90-210 Blue180°401.8230 ft30–55 psi: 1.58–2.13 GPM
MP3000 90-210 Blue210°402.1230 ft30–55 psi: 1.84–2.49 GPM
MP3000 210-270 Yellow210°402.1230 ft30–55 psi: 1.84–2.49 GPM
MP3000 210-270 Yellow270°402.7330 ft30–55 psi: 2.37–3.22 GPM
MP3000 360 Gray360°403.6430 ft30–55 psi: 3.15–4.27 GPM
MP3500 90-210 Light Brown90°401.2835 ft30–55 psi: 1.13–1.5 GPM
MP3500 90-210 Light Brown180°402.8635 ft30–55 psi: 2.24–3.28 GPM
MP3500 90-210 Light Brown210°403.2935 ft30–55 psi: 2.84–3.94 GPM
MP Corner 45-105 Turquoise45°400.1914 ft30–55 psi: 0.17–0.23 GPM
MP Corner 45-105 Turquoise90°400.3914 ft30–55 psi: 0.34–0.46 GPM
MP Corner 45-105 Turquoise105°400.4514 ft30–55 psi: 0.39–0.53 GPM
MP800SR 90-210 Orange/Gray90°400.2310 ft30–55 psi: 0.17–0.28 GPM
MP800SR 90-210 Orange/Gray180°400.4210 ft30–55 psi: 0.33–0.5 GPM
MP800SR 90-210 Orange/Gray210°400.4310 ft30–55 psi: 0.35–0.56 GPM
MP800SR 360 Lime Green/Gray360°400.7810 ft30–55 psi: 0.66–0.98 GPM
MP-LCS-515 Ivory—400.19—30–55 psi: 0.17–0.24 GPM
MP-RCS-515 Copper—400.19—30–55 psi: 0.17–0.24 GPM
MP-SS-530 Brown—400.38—30–55 psi: 0.33–0.47 GPM

Rain Bird MPR fixed

ModelArcAt psiGPMRadiusFull range on chart
5Q90°300.15 ft15–30 psi: 0.07–0.1 GPM
5H180°300.25 ft15–30 psi: 0.14–0.2 GPM
5F360°300.415 ft15–30 psi: 0.29–0.41 GPM
8Q90°300.268 ft15–30 psi: 0.18–0.26 GPM
8H180°300.528 ft15–30 psi: 0.37–0.52 GPM
8F360°301.058 ft15–30 psi: 0.74–1.05 GPM
10Q90°300.3910 ft15–30 psi: 0.29–0.39 GPM
10H180°300.7910 ft15–30 psi: 0.58–0.79 GPM
10F360°301.5810 ft15–30 psi: 1.16–1.58 GPM
12Q90°300.6512 ft15–30 psi: 0.45–0.65 GPM
12H180°301.312 ft15–30 psi: 0.9–1.3 GPM
12F360°302.612 ft15–30 psi: 1.8–2.6 GPM
15Q90°300.9215 ft15–30 psi: 0.65–0.92 GPM
15H180°301.8515 ft15–30 psi: 1.3–1.85 GPM
15F360°303.715 ft15–30 psi: 2.6–3.7 GPM

Rain Bird VAN fixed

ModelArcAt psiGPMRadiusFull range on chart
4-VAN90°300.294 ft15–30 psi: 0.21–0.29 GPM
4-VAN180°300.454 ft15–30 psi: 0.32–0.45 GPM
4-VAN270°300.734 ft15–30 psi: 0.52–0.73 GPM
4-VAN330°300.884 ft15–30 psi: 0.62–0.88 GPM
6-VAN90°300.376 ft15–30 psi: 0.26–0.37 GPM
6-VAN180°300.66 ft15–30 psi: 0.42–0.6 GPM
6-VAN270°301.16 ft15–30 psi: 0.79–1.1 GPM
6-VAN330°301.26 ft15–30 psi: 0.85–1.2 GPM
8-VAN90°300.728 ft15–30 psi: 0.51–0.72 GPM
8-VAN180°301.198 ft15–30 psi: 0.84–1.19 GPM
8-VAN270°301.558 ft15–30 psi: 1.11–1.55 GPM
8-VAN330°301.78 ft15–30 psi: 1.21–1.7 GPM
10-VAN90°300.7510 ft15–30 psi: 0.48–0.75 GPM
10-VAN180°301.4510 ft15–30 psi: 0.97–1.45 GPM
10-VAN270°302.110 ft15–30 psi: 1.45–2.1 GPM
10-VAN360°302.610 ft15–30 psi: 1.93–2.6 GPM
12-VAN90°300.5912 ft15–30 psi: 0.39–0.59 GPM
12-VAN180°301.1812 ft15–30 psi: 0.78–1.18 GPM
12-VAN270°301.7712 ft15–30 psi: 1.17–1.77 GPM
12-VAN360°302.3612 ft15–30 psi: 1.56–2.36 GPM
15-VAN90°300.9215 ft15–30 psi: 0.65–0.92 GPM
15-VAN180°301.8515 ft15–30 psi: 1.3–1.85 GPM
15-VAN270°302.7815 ft15–30 psi: 1.95–2.78 GPM
15-VAN360°303.715 ft15–30 psi: 2.6–3.7 GPM
18-VAN90°301.3318 ft15–30 psi: 1.05–1.33 GPM
18-VAN180°302.6618 ft15–30 psi: 2.11–2.66 GPM
18-VAN270°303.9918 ft15–30 psi: 3.16–3.99 GPM
18-VAN360°305.3218 ft15–30 psi: 4.21–5.32 GPM

Rain Bird HE-VAN fixed

ModelArcAt psiGPMRadiusFull range on chart
HE-VAN-0890°300.298 ft15–30 psi: 0.21–0.29 GPM
HE-VAN-08180°300.598 ft15–30 psi: 0.41–0.59 GPM
HE-VAN-08270°300.888 ft15–30 psi: 0.62–0.88 GPM
HE-VAN-08360°301.178 ft15–30 psi: 0.83–1.17 GPM
HE-VAN-1090°300.4510 ft15–30 psi: 0.32–0.45 GPM
HE-VAN-10180°300.8910 ft15–30 psi: 0.63–0.89 GPM
HE-VAN-10270°301.3410 ft15–30 psi: 0.95–1.34 GPM
HE-VAN-10360°301.7810 ft15–30 psi: 1.26–1.78 GPM
HE-VAN-1290°300.5912 ft15–30 psi: 0.42–0.59 GPM
HE-VAN-12180°301.1812 ft15–30 psi: 0.84–1.18 GPM
HE-VAN-12270°301.7712 ft15–30 psi: 1.25–1.77 GPM
HE-VAN-12360°302.3712 ft15–30 psi: 1.67–2.37 GPM
HE-VAN-1590°300.9315 ft15–30 psi: 0.65–0.93 GPM
HE-VAN-15180°301.8515 ft15–30 psi: 1.31–1.85 GPM
HE-VAN-15270°302.7815 ft15–30 psi: 1.96–2.78 GPM
HE-VAN-15360°303.715 ft15–30 psi: 2.62–3.7 GPM

Rain Bird R-VAN rotary

ModelArcAt psiGPMRadiusFull range on chart
R-VAN1490°450.3214 ft30–55 psi: 0.28–0.39 GPM
R-VAN14180°450.6314 ft30–55 psi: 0.56–0.78 GPM
R-VAN14210°450.7314 ft30–55 psi: 0.65–0.91 GPM
R-VAN14270°450.9414 ft30–55 psi: 0.84–1.17 GPM
R-VAN14-360360°451.2714 ft30–55 psi: 1.1–1.45 GPM
R-VAN1890°450.517 ft30–55 psi: 0.42–0.58 GPM
R-VAN18180°451.0117 ft30–55 psi: 0.85–1.09 GPM
R-VAN18210°451.1717 ft30–55 psi: 0.98–1.26 GPM
R-VAN18270°451.5117 ft30–55 psi: 1.26–1.62 GPM
R-VAN18-360360°451.8517 ft30–55 psi: 1.65–2.11 GPM
R-VAN2490°450.8423 ft30–55 psi: 0.6–0.96 GPM
R-VAN24180°451.6823 ft30–55 psi: 1.2–1.92 GPM
R-VAN24210°451.9623 ft30–55 psi: 1.4–2.24 GPM
R-VAN24270°452.5223 ft30–55 psi: 1.8–2.88 GPM
R-VAN24-360360°453.4823 ft30–55 psi: 2.35–3.74 GPM
R-VAN-LCS—450.24—30–55 psi: 0.18–0.28 GPM
R-VAN-RCS—450.24—30–55 psi: 0.18–0.28 GPM
R-VAN-SST—450.48—30–55 psi: 0.36–0.56 GPM

Hunter Pro Adjustable fixed

ModelArcAt psiGPMRadiusFull range on chart
4A Light Green45°300.134 ft20–40 psi: 0.1–0.16 GPM
4A Light Green90°300.224 ft20–40 psi: 0.19–0.25 GPM
4A Light Green120°300.344 ft20–40 psi: 0.28–0.37 GPM
4A Light Green180°300.454 ft20–40 psi: 0.34–0.48 GPM
4A Light Green240°300.684 ft20–40 psi: 0.58–0.8 GPM
4A Light Green270°300.734 ft20–40 psi: 0.62–0.84 GPM
4A Light Green360°300.84 ft20–40 psi: 0.66–0.9 GPM
6A Light Blue45°300.186 ft20–40 psi: 0.15–0.19 GPM
6A Light Blue90°300.376 ft20–40 psi: 0.3–0.4 GPM
6A Light Blue120°300.446 ft20–40 psi: 0.37–0.48 GPM
6A Light Blue180°300.66 ft20–40 psi: 0.5–0.68 GPM
6A Light Blue240°300.886 ft20–40 psi: 0.73–1.02 GPM
6A Light Blue270°301.16 ft20–40 psi: 0.88–1.2 GPM
6A Light Blue360°301.266 ft20–40 psi: 1.05–1.4 GPM
8A Brown45°300.228 ft20–40 psi: 0.18–0.25 GPM
8A Brown90°300.448 ft20–40 psi: 0.36–0.5 GPM
8A Brown120°300.598 ft20–40 psi: 0.48–0.67 GPM
8A Brown180°300.888 ft20–40 psi: 0.72–1 GPM
8A Brown240°301.178 ft20–40 psi: 0.96–1.33 GPM
8A Brown270°301.328 ft20–40 psi: 1.08–1.5 GPM
8A Brown360°301.768 ft20–40 psi: 1.44–2 GPM
10A Red45°300.2510 ft20–40 psi: 0.2–0.3 GPM
10A Red90°300.510 ft20–40 psi: 0.4–0.59 GPM
10A Red120°300.6710 ft20–40 psi: 0.53–0.79 GPM
10A Red180°30110 ft20–40 psi: 0.8–1.18 GPM
10A Red240°301.3310 ft20–40 psi: 1.07–1.57 GPM
10A Red270°301.510 ft20–40 psi: 1.2–1.77 GPM
10A Red360°30210 ft20–40 psi: 1.6–2.36 GPM
12A Green45°300.3212 ft20–40 psi: 0.25–0.42 GPM
12A Green90°300.6312 ft20–40 psi: 0.5–0.84 GPM
12A Green120°300.8412 ft20–40 psi: 0.67–1.12 GPM
12A Green180°301.2612 ft20–40 psi: 1–1.68 GPM
12A Green240°301.6812 ft20–40 psi: 1.33–2.24 GPM
12A Green270°301.8912 ft20–40 psi: 1.5–2.52 GPM
12A Green360°302.5212 ft20–40 psi: 2–3.36 GPM
15A Black45°300.4715 ft20–40 psi: 0.39–0.57 GPM
15A Black90°300.9315 ft20–40 psi: 0.77–1.13 GPM
15A Black120°301.2415 ft20–40 psi: 1.03–1.51 GPM
15A Black180°301.8615 ft20–40 psi: 1.54–2.26 GPM
15A Black240°302.4815 ft20–40 psi: 2.05–3.01 GPM
15A Black270°302.7915 ft20–40 psi: 2.31–3.39 GPM
15A Black360°303.7215 ft20–40 psi: 3.08–4.52 GPM
17A Gray45°300.5817 ft20–40 psi: 0.49–0.69 GPM
17A Gray90°301.1517 ft20–40 psi: 0.97–1.38 GPM
17A Gray120°301.5317 ft20–40 psi: 1.29–1.84 GPM
17A Gray180°302.317 ft20–40 psi: 1.94–2.76 GPM
17A Gray240°303.0717 ft20–40 psi: 2.59–3.68 GPM
17A Gray270°303.4517 ft20–40 psi: 2.91–4.14 GPM
17A Gray360°304.617 ft20–40 psi: 3.88–5.52 GPM

Hunter Pro Fixed fixed

ModelArcAt psiGPMRadiusFull range on chart
8Q Brown90°300.248 ft20–40 psi: 0.2–0.28 GPM
8T Brown120°300.328 ft20–40 psi: 0.26–0.38 GPM
8H Brown180°300.478 ft20–40 psi: 0.38–0.54 GPM
8F Brown360°300.978 ft20–40 psi: 0.78–1.13 GPM
10Q Red90°300.4210 ft20–40 psi: 0.34–0.49 GPM
10T Red120°300.5710 ft20–40 psi: 0.46–0.66 GPM
10H Red180°300.8810 ft20–40 psi: 0.7–1.03 GPM
10F Red360°301.5910 ft20–40 psi: 1.29–1.84 GPM
12Q Green90°300.6712 ft20–40 psi: 0.54–0.78 GPM
12T Green120°300.8912 ft20–40 psi: 0.72–1.04 GPM
12H Green180°301.312 ft20–40 psi: 1.05–1.52 GPM
12F Green360°302.712 ft20–40 psi: 2.17–3.15 GPM
15Q Black90°300.9715 ft20–40 psi: 0.78–1.14 GPM
15T Black120°301.315 ft20–40 psi: 1.04–1.52 GPM
15H Black180°301.8615 ft20–40 psi: 1.51–2.16 GPM
15F Black360°303.7515 ft20–40 psi: 3.04–4.36 GPM

Hunter PGP Ultra rotor

ModelArcAt psiGPMRadiusFull range on chart
PGP Ultra 1.5 Blue Blue—451.531 ft25–65 psi: 1.2–1.9 GPM
PGP Ultra 2.0 Blue Blue—45234 ft25–65 psi: 1.4–2.3 GPM
PGP Ultra 2.5 Blue Blue—452.535 ft25–65 psi: 1.7–2.9 GPM
PGP Ultra 3.0 Blue Blue—45338 ft25–65 psi: 2.2–3.7 GPM
PGP Ultra 4.0 Blue Blue—45440 ft25–65 psi: 3–4.8 GPM
PGP Ultra 5.0 Blue Blue—45542 ft25–65 psi: 3.7–6.2 GPM
PGP Ultra 6.0 Blue Blue—45643 ft25–65 psi: 4.3–7.3 GPM
PGP Ultra 8.0 Blue Blue—45844 ft25–65 psi: 6–9.8 GPM

Hunter I-20 rotor

ModelArcAt psiGPMRadiusFull range on chart
I-20 1.5 Blue Blue—451.531 ft25–65 psi: 1.2–1.9 GPM
I-20 2.0 Blue Blue—45234 ft25–65 psi: 1.4–2.3 GPM
I-20 2.5 Blue Blue—452.535 ft25–65 psi: 1.7–2.9 GPM
I-20 3.0 Blue Blue—45338 ft25–65 psi: 2.2–3.7 GPM
I-20 4.0 Blue Blue—45440 ft25–65 psi: 3–4.8 GPM
I-20 5.0 Blue Blue—45542 ft25–65 psi: 3.7–6.2 GPM
I-20 6.0 Blue Blue—45643 ft25–65 psi: 4.3–7.3 GPM
I-20 8.0 Blue Blue—45844 ft25–65 psi: 6–9.8 GPM

Rain Bird 5000 rotor

ModelArcAt psiGPMRadiusFull range on chart
5000 Rain Curtain 1.5—451.5435 ft25–65 psi: 1.12–1.86 GPM
5000 Rain Curtain 2.0—452.0737 ft25–65 psi: 1.5–2.52 GPM
5000 Rain Curtain 2.5—452.5137 ft25–65 psi: 1.81–3.01 GPM
5000 Rain Curtain 3.0—453.0940 ft25–65 psi: 2.26–3.78 GPM
5000 Rain Curtain 4.0—454.0142 ft25–65 psi: 2.91–4.83 GPM
5000 Rain Curtain 5.0—455.0945 ft25–65 psi: 3.72–6.16 GPM
5000 Rain Curtain 6.0—456.0146 ft25–65 psi: 4.25–7.22 GPM
5000 Rain Curtain 8.0—458.0347 ft25–65 psi: 5.9–9.63 GPM

Rain Bird 5000 MPR rotor

ModelArcAt psiGPMRadiusFull range on chart
5000-MPR-25-Q Red90°45125 ft25–65 psi: 0.74–1.21 GPM
5000-MPR-25-T Red120°451.3825 ft25–65 psi: 1–1.67 GPM
5000-MPR-25-H Red180°451.9825 ft25–65 psi: 1.44–2.41 GPM
5000-MPR-25-F Red360°453.8225 ft25–65 psi: 2.78–4.63 GPM
5000-MPR-30-Q Green90°451.430 ft25–65 psi: 1.03–1.69 GPM
5000-MPR-30-T Green120°451.8530 ft25–65 psi: 1.34–2.24 GPM
5000-MPR-30-H Green180°452.9630 ft25–65 psi: 2.15–3.6 GPM
5000-MPR-30-F Green360°455.7830 ft25–65 psi: 4.24–6.92 GPM
5000-MPR-35-Q Beige90°451.9235 ft25–65 psi: 1.4–2.31 GPM
5000-MPR-35-T Beige120°452.4635 ft25–65 psi: 1.77–2.99 GPM
5000-MPR-35-H Beige180°453.8135 ft25–65 psi: 2.75–4.62 GPM
5000-MPR-35-F Beige360°457.5835 ft25–65 psi: 5.36–9.18 GPM

Rain Bird 1400 PC Bubbler bubbler

ModelArcAt psiGPMRadiusFull range on chart

Rain Bird 1300A-F Bubbler bubbler

ModelArcAt psiGPMRadiusFull range on chart
1300A-F360°301.7—10–60 psi: 1–2.3 GPM

Hunter PCB bubbler

ModelArcAt psiGPMRadiusFull range on chart

Rain Bird Xeri-Bug drip

ModelFlowPressure rangePC
XB-05PC Blue0.5 GPH15–50 psiYes
XB-10PC Black1 GPH15–50 psiYes
XB-20PC Red2 GPH15–50 psiYes

Rain Bird PC Modules drip

ModelFlowPressure rangePC
PC-05 Light Brown5 GPH10–50 psiYes
PC-07 Violet7 GPH10–50 psiYes
PC-10 Green10 GPH10–50 psiYes
PC-12 Dark Brown12 GPH10–50 psiYes
PC-18 White18 GPH10–50 psiYes
PC-24 Orange24 GPH10–50 psiYes

Hunter HE Point Source Emitter drip

ModelFlowPressure rangePC
HE-050-B Blue0.5 GPH20–50 psiYes
HE-10-B Black1 GPH20–50 psiYes
HE-20-B Red2 GPH20–50 psiYes
HE-40-B Tan4 GPH20–50 psiYes
HE-60-B Orange6 GPH20–50 psiYes

From the manufacturers' published performance charts (Hunter, Rain Bird). Used by the MyWaterBudget field app for every flow check.

Connecting a controller to MyWaterBudget

Only Hydrawise and Rachio send live data. Every other controller still works: MyWaterBudget gives the minutes to set each month and the rain alerts.

ControllerModelsHow it works with MyWaterBudget
Hydrawise HunterHPC, Pro-HC, HC, X2 with Wand, ICC2 with HydrawiseConnects live with an API key. In the Hydrawise app or hydrawise.com: menu (top left) → Account Details → Account Settings → Generate API Key. Copy the whole key. Then paste it in MyWaterBudget where it asks for the Hydrawise API key.
RachioRachio 3, Rachio 2, Gen 1Connects live with an API key. On a computer, sign in at app.rach.io → your name (top right) → Account Settings → Get API Key. Copy the whole key. Then paste it in MyWaterBudget where it asks for the Rachio API key.
Rain Bird Wi-Fi (LNK / LNK2)ESP-TM2, ESP-Me3, ESP-Me, ARC8Virtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand.
Orbit B-hyveB-hyve Smart, B-hyve XR, hose timersVirtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand.
RainMachineTouch HD, Mini-8, ProVirtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand.
Wyze SprinklerSprinkler ControllerVirtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand.
Weathermatic SmartLinkSmartLink (commercial)Virtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand.
Hunter (not Wi-Fi)X-Core, X2 without Wand, Pro-C, ICC2Virtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand.
Rain Bird (not Wi-Fi)ESP-TM2, ESP-Me, SSTVirtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand.
IrritrolRain Dial, Total Control, Kwik DialVirtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand.
Orbit (not Wi-Fi)Dial and push-button timersVirtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand.
K-RainRPS, Pro EXVirtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand.
Other / not sureAny timerVirtual smart controller: MyWaterBudget works out the schedule and the rain skips; you or your pro set the controller by hand.

Programming controllers, by make and model

The buttons for the controllers techs see most in Arizona and Oregon: Hunter, Rain Bird, Toro, Irritrol, Weathermatic, K-Rain, Orbit and Rachio. Written from each maker's owner's manual. Minutes come from MyWaterBudget's Water Check, not from guesses.

Jump to: Hunter X-Core · Hunter Pro-C (PCC / P2C) · Hunter / Hydrawise HPC, HCC, Pro-HC (Wi-Fi touchscreen) · Rain Bird ESP-TM2 · Rain Bird ESP-ME3 (and ESP-Me) · Toro TMC-212 · Irritrol (Toro) Rain Dial-R (RD-600 / 900 / 1200) · Weathermatic SmartLine (SL800 / SL1600 / SL4800) · K-Rain Pro EX 2.0 (and Pro EX Wi-Fi) · Orbit B-hyve XR (Wi-Fi) · Rachio Rachio 3 (Wi-Fi)

Hunter X-Core

How to spot it: Gray dial controller, small LCD, + / − and arrow buttons, a program button for A/B/C, and a Sensor Bypass slide switch. Indoor model plugs into an outlet; outdoor model has the transformer inside and a locking door.

Source: Hunter X-Core Owner's Manual (hunterirrigation.com, LIT-397).

Hunter Pro-C (PCC / P2C)

How to spot it: Larger gray dial controller with a PRG button, modular station slots (4-station base, adds 3, 9 or 16 station modules up to 23, or decoders to 32), a Sensor Bypass button, and a reset button on the back of the facepack.

Source: Hunter Pro-C (P2C) Owner's Manual (hunterirrigation.com).

Hunter / Hydrawise HPC, HCC, Pro-HC (Wi-Fi touchscreen)

How to spot it: Color touchscreen with Home, Zones, Settings and Status. Programmed in the Hydrawise app or hydrawise.com. HPC is the Pro-C body with a Wi-Fi facepack (4–32 zones).

Source: Hydrawise App Owner's Manual (Hunter Industries).

Rain Bird ESP-TM2

How to spot it: Rain Bird gray dial controller, 4 to 12 stations (no modules), Back/Next and + / − buttons, a Program Select button, works with the LNK Wi-Fi module.

Source: Rain Bird ESP-TM2 Controller User Manual (rainbird.com).

Rain Bird ESP-ME3 (and ESP-Me)

How to spot it: Rain Bird modular dial controller: 4-station base, 3- and 6-station modules up to 22 stations, ALARM light, Hold to Start button, works with the LNK Wi-Fi module.

Source: Rain Bird ESP-ME3 Advanced User Manual; Rain Bird support (ESP-Me factory reset).

Toro TMC-212

How to spot it: Toro dial controller, 2 to 12 stations with 2-station modules, a PROGRAMS slide switch (A/B/C), +/ON, −/OFF, NEXT and MANUAL START buttons, rain sensor switches inside.

Source: Toro TMC-212 User's Guide (373-0402).

Irritrol (Toro) Rain Dial-R (RD-600 / 900 / 1200)

How to spot it: Irritrol dial controller, 6, 9 or 12 stations, a Function switch (Run / Set Programs / Off-Stop), a Program switch (A/B/C), + / − buttons, Manual and Semi-Auto buttons, takes a 9V battery.

Source: Irritrol Rain Dial-R User's Guide (373-0538).

Weathermatic SmartLine (SL800 / SL1600 / SL4800)

How to spot it: Weathermatic dial controller with PGM, NEXT/BACK, UP/DOWN and START MANUAL PROGRAM buttons, a RAIN/FREEZE button, and status lights. SL800 4–8 zones, SL1600 4–16, SL4800 12–48. Optional SLW on-site weather sensor for SMART mode.

Source: Weathermatic SmartLine Owner's Manual.

K-Rain Pro EX 2.0 (and Pro EX Wi-Fi)

How to spot it: K-Rain dial controller with a big backlit display, 4-station base module expanding to 16 with 4-station modules, PROGRAM SELECT and RAIN SENSOR SELECT buttons, MANUAL START/NEXT, BACK/NEXT and UP/DOWN. Wi-Fi version adds a hub and the K-Rain app.

Source: K-Rain Pro EX 2.0 Installation, Programming and Operation Manual.

Orbit B-hyve XR (Wi-Fi)

How to spot it: Small white Orbit timer with one button and a light ring, programmed only in the B-hyve app. 8 or 16 zones.

Source: Orbit B-hyve XR Quick Start Guide.

Rachio Rachio 3 (Wi-Fi)

How to spot it: White square controller with a light bar and on-unit Run, Pause and Skip buttons. 8 or 16 zones. Programmed in the Rachio app.

Source: Rachio support (Rachio 3 FAQ, Weather Intelligence Plus).

Troubleshooting controllers, valves and wiring

Controller wiring is 24-volt, but the controller plugs into house power. Turn the power off before you open it. If you're not sure, call a pro.

A zone won't come on

  1. Controller first. Check the display is on; no rain delay, rain sensor or "sensor off" is showing; seasonal adjust or water budget isn't at 0%; and that program has a start time and run time.
  2. Run the zone by hand from the controller. Then open the valve by hand: on most Hunter and Rain Bird valves, turn the solenoid about a half turn counterclockwise (or open the bleed screw). Snug it back clockwise to close.
  3. Opens by hand, not from the controller = an electrical problem. Go to the meter checks below.
  4. Won't open by hand either = a water problem. Check the shut-off and backflow are open, the flow control isn't screwed down, and look for debris or a torn diaphragm.

Meter checks (controller off for resistance, on for voltage)

CheckNormalWhat it means if not
Wall power into the controller105–129 VACOutside that: electrician. Not a sprinkler fix.
Transformer output24–28 VACOutside that: bad transformer.
Station terminal to COM, zone running24–28 VACLow or none on one station: controller output. Fine at the clock but low at the valve: wire or splice.
Station to COM, power off, wires on20–60 ohmsUnder 20: short, crossed wires, or two valves on one station (more valves read lower). Over 60: broken wire, bad splice or bad solenoid.
Solenoid alone, wires off at the valveRain Bird: 20–60 ohms (G4 solenoid 30–39 nominal). Hunter AC: about 25–35 ohms0 or "open": replace the solenoid. Good solenoid but bad reading from the clock: the field wire.
Field wires alone, solenoid offAbout 5 ohms or less (shorted at the valve end)High: broken wire or bad splice between clock and valve.

Battery controllers use DC-latching solenoids, not 24 VAC. Hunter's DC-latching solenoid reads about 4.8 ohms and runs on 6–9 VDC. Don't mix AC and DC solenoids.

A valve won't shut off or keeps weeping

Weak heads, short throw, dry spots

Drip zone not doing its job

Wi-Fi controller offline

Voltage and resistance ranges: Rain Bird multimeter troubleshooting guides and G4 solenoid guide; Hunter support pages (valve not opening, valve not closing, solenoids). Field steps: Robert Kemp, 18 years running an East Valley irrigation company.